300781 • 1/2019 • H.S.
43 of 70
Operating Instruction
High Pressure Cleaner cold water, mobile
Series 3x3
5 Commissioning
5.3
Establishing the electrical mains connection
WARNING
Ensure that the electrical connection is properly installed.
Only connect the device to voltage sources earthed in accordance with
the safety regulations (mains connection of buildings or mains junction
box e.g. on construction sites).
The connection plugs must not lie on the floor and must always be dry.
Do not touch the connectors with wet hands.
All live parts in the intended working area for cleaning work, e.g. de-
vices, cables, sockets etc. must be water-jet proof in accordance with the
safety regulations.
Depending on device, the electrical mains connection (mains connection of
buildings or mains junction box e.g. on construction sites) must adhere the
Technical Data (see Section 3.14) and
●
comply with the electrical values indicated on the type plate of the
device
●
ensure trouble-free constant operation.
The mains connection must be equipped with a residual current circuit
breaker 30 mA and protected via circuit breaker as follows
●
Mains voltage 230 VAC with 16 A (slow blow)
●
Mains voltage 3 x 400 VAC with 3 x 16 A (slow blow).
The high pressure cleaner is supplied with a 5 m long mains cable.
When using extension cables, the relevant national safety regulations must
be observed. The cross section of the individual cable wires for extension
cables must be at least
●
1,5 mm² for a length up to 10 m
●
2,5 mm² bei einer Länge von mehr als 10 m.
Use extension cable H07RN-F 3 G, 1,5 mm² or 2,5 mm². The plug
connections must be water-jet proof in accordance with safety regulations.
When using a cable drum, the extension cable must always be unwound
completely.
For the electrical connection proceed as follows:
Make sure, the device switch 0/I (3, Fig. 6 - 1) is switched off
(position 0).
Unwind the mains cable from the holder and place it on the floor.
When using extension cables, unwind the cable from the drum and
place it on the floor.
Plug the mains cable plug into the socket.