Set date / time 

Adjusts the internal clock of the block to PC system time. 

Read version number 

Read the version number of Net Scale firmware. 

Test scale 

Start display test at scale.  

Zero: 

Set the corresponding scale to zero 

Set/delete Tare 

Moves display value of scale to tare memory. When tare is set, 
the value is written from memory back to the display. 

Send fix tare 

Fix tare input field is written to the tare memory. 

„0“ deletes 

the tare memory.  

Read measured value 

Reads the value from scale and writes it to the response field. 

Registration network 

Reads  the  measured  value  and  stores  a  data  record  in  the 
verifiable memory. 

Registration manual 

Registration of a weight for old net scale systems with only one 
scale (not in use with new systems). 

Clear 

Deletes content from „Response from Net

-

Scale“ field.

 

Execute 

Transmit the settins to Net-Scale. 

 
Table 8 

 Functions 

 

 
Via service tab the IP-address and INI-file can be changed. 
 

      

 

 
Figure 5 - Service settings 

 

 
Overwrite  IP-address  and 

confirm  with  „Change“  button  (only  works  if  DHCP  is  disabled,  see  also 

section UDP Protocol configuration). 
 
 

 

Содержание Net-Scale V13

Страница 1: ...V1 2...

Страница 2: ...Set Zero 01 11 Set Tare 02 11 Delete Tare 03 11 Set Fixtare 04 11 Select scale 05 11 Register weight at stability 10 11 Manual registration 12 12 Firmware version F0 12 Set date time F1 12 Query for...

Страница 3: ...design features This allows you to easily distinguish the following elements Normal text Enumerations Action steps Table titles and illustrations are printed in bold Tips contain additional informati...

Страница 4: ...Table 1 Technical data...

Страница 5: ...0 4 2 EN 61000 4 3 EN 61000 4 4 EN 61000 4 5 EN 61000 4 6 EN 61000 4 11 according to directive 2014 30 EU elektromagnetic compatibiltiy EN 60950 1 2006 in accordance with Directive 2014 35 EU Low Volt...

Страница 6: ...by qualified customer service This devise is not waterproof To avoid the risk of electric shock protect the device from dripping water splashing water rain and moisture Do not place any fire source on...

Страница 7: ...na 2 Network connection LED status green processor in use yellow network connected 3 Power supply connection socket 4 Slot for SD card The following accessories are included in the scope of delivery 1...

Страница 8: ...mware 2 12 Activate communication to scales permanently By entering the scale number in the INI file a permanent connection is established independent of the configuration of the network interface A s...

Страница 9: ...187 A basic understanding of the IP UDP or TCP protocol is assumed Several commands can be lined up in a data record separated by semicolon Only the last command may generate a feedback For example se...

Страница 10: ...s activated which guarantees connection security An automatic timeout of 120 seconds is stored for the TCP protocol When the TCP protocol is activated connection security is guaranteed An automatic ti...

Страница 11: ...01 16 No feedback This command is only available with active communication with the scale see F8 page 13 Alternatively a scale can also be activated automatically by means of INI file parameter ACT se...

Страница 12: ...i iii iii iii IP address c Block check character E1 Error Alibi memory full E2 Error no standstil overload negative weight etc E4 Error Communication with scale is interrupted or scale is not connecte...

Страница 13: ...angeover may only be carried out once for initialization of the Net Scale module If the channel change is permanently combined with other commands the function of the unit is significantly restricted...

Страница 14: ...dd ssttttt ee c x Status byte 00 Stability indication 03 tared 04 Weighing range 06 always active f Errorcode 10 Overload 11 Test 14 battery empty 16 always active ss Space nnnnn Measured value 5 digi...

Страница 15: ...02 01 00 ASCII Binary 0 1 0 0 0 0 0 0 Stability indication no Tare no Weighing range Range 1 corresponds to 0 17 16 15 14 13 12 11 10 ASCII Binary 0 1 0 0 0 0 0 1 A Stability indication no Tare no Wei...

Страница 16: ...h an blockcheck character This block check character is formed by exclusive OR nexus of all characters of the data set and then OR with 0x40 When receiving such a secured data set the integrity of the...

Страница 17: ...h digit of weight indication e g 10320 kg 6 Digit 3 3rd digit of weight indication e g 10320 kg 7 Digit 2 5nd digit of weight indication e g 10320 kg 8 Digit 1 1st digit of weight indication e g 10320...

Страница 18: ...Sign always plus 19 Digit 5 5th digit of Tare 20 Digit 4 4th digit of Tare 21 Digit 3 3rd digit of Tare 22 Digit 2 2nd digit of Tare 23 Digit 1 1st digit of Tare 24 x Checksum 25 x Checksum 28 03 H En...

Страница 19: ...the scale This can be changed in scale setup menue see chapter Change frequency and scale number 00 01 433 075 15 434 000 02 433 125 16 434 075 03 433 175 17 434 150 04 433 225 18 434 225 05 433 275...

Страница 20: ...By pressing the TEST Button the crane scale display shows the current setting parameter in following sequences Parameter No 4 and No 5 are relevant Table 6 Parameter settings To change the scale and...

Страница 21: ...ess the TEST key until P14 appears in the display Parameter P14 is used to set the scale number Press the TARE key to activate the parameter Then use the TEST key to select a desired value between 01...

Страница 22: ...ashes several times on the display This indicates that the parameter change has been successfully stored To exit the SETUP menu press the Power On and Power Off buttons simultaneously or interrupt the...

Страница 23: ...ou are familiar with the setting changes In the event of an error it may no longer be possible to reach the net scale via the network The demo tool automatically finds all available device blocks in t...

Страница 24: ...emory Read measured value Reads the value from scale and writes it to the response field Registration network Reads the measured value and stores a data record in the verifiable memory Registration ma...

Страница 25: ...SD card Data is transfered via ftp to your PC and stored in installation folder of Scale 99 Software Ensure that port 21 is available for ftp communication at your network The file S99_mem exe can be...

Страница 26: ...folder of Scale 99 Cancel Cancels the action Print Prints the contents of the alibi memory Month Selection of month for the long term memory Year Selection of year for the long term memory Long term...

Страница 27: ...nds of the weight 25 Digit 3 Hundreds of the weight 28 Digit 2 Tens of the weight 29 Digit 1 Unit of the weight 30 k k 31 g g 32 Blank 20H or 0 33 free space HEX20 34 Blank 20H or 0 free space HEX20 3...

Страница 28: ...erated outside the radio link switched off or if the checksum of the scales dataset has an error The latter happens quite often if the radio link is disturbed by a different radio link or atmospheric...

Страница 29: ...Do you need our support No problem just call us free of charge Reach our technical experts from Monday to Thursday between 8 am 4 pm CET and Friday between 8 am 12 am CET...

Страница 30: ......

Отзывы: