![EHC ECOSAVE 21K Скачать руководство пользователя страница 41](http://html.mh-extra.com/html/ehc/ecosave-21k/ecosave-21k_instruction-manual_2368486041.webp)
Instructing the End User
16.
Error Code List
17.
Handing over the Instructions
16.1
Hand over the instructions and the checklist, and explain the
following points to the end user.
Explanation of the data plate
t
Countermeasures for gas leaks
t
Risks of fire due to combustibles, dust, and explosives
t
Risks of placing flammable liquids near the appliance
t
Risks of placing oxides such as chlorine near the appliance
t
Risks of placing rubbish near the appliance
t
Frost proof insulation
t
Precautions about the intake and exhaust flue
t
Precautions about the condensate drain pipe
t
Necessity of annual periodical checks by service engineers
t
Cleaning methods
t
Precautions about not using the appliance for long periods of
t
time
Showing How to Operate
16.2
Use the “Instructions for Use”, to explain the following points
concerning how to operate the appliance. Also, configure the
settings for the user.
Appliance functions
t
Operating the control panel
t
Power ON/OFF
-
Display details
-
Temperature settings for central heating
-
Temperature settings for domestic hot water
-
Explain and operate the service menu
-
Operations when error codes are displayed
-
Precautions against using the appliance incorrectly.
t
Countermeasures for appliance malfunctions
t
Location and operation of the gas shutoff valve
t
Explain the following error codes if the appliance malfunctions.
The error codes will blink and be displayed on the digital control
Panel.
Error
Code
Reason
Action required
E02
Low water-level
Contact Engineer.
E03
Ignition failure
Reset the appliance.
E04
Flame simulation
E05
Supply water thermistor: Open
E06
Supply water thermistor: Short
E07
Hot water thermistor: Open
E08
Hot water thermistor: Short
E09
Abnormal fan
Reset the appliance.
E10
Abnormal air pressure
Reset the appliance.
E11
Water pressure sensor fault
E12
Flame failure
Reset the appliance.
E15
Abnormal BMC
Reset the appliance.
E16
Over heat: Heat exchanger
Reset the appliance.
E17
DIP Switch Setting fault
Reset the appliance.
E18
Return water thermistor: Open
E19
Return water thermistor: Short
E21
Inlet water thermistor: Open
E22
Inlet water thermistor: Short
E27
Abnormal air pressure sensor
Reset the appliance.
E30
Over heat: Exhaust
Reset the appliance.
E40
Outdoor thermistor: Short
E93
Key button failure
Contact Engineer.
Contact Engineer.
Contact Engineer.
Contact Engineer.
Contact Engineer.
Contact Engineer.
Contact Engineer.
Contact Engineer.
Contact Engineer.
Contact Engineer.
Contact Engineer.
Contact Engineer.
Ensure client is made aware of Warranty Conditions.
41
Error Code List
EHC
Instructing the End User
Содержание ECOSAVE 21K
Страница 42: ...l a c i r t c e l E 18 Wiring Diagram 18 1 Electrical 42 EHC ...
Страница 45: ...Water Way Parts 19 3 82 120 45 Parts List EHC ...
Страница 52: ......
Страница 53: ......
Страница 54: ......
Страница 56: ...EHC Ltd ISO 9001 2008 ...