Electrical Connections and Settings
32
EHC
Connecting the Controller,
14.4
Accessories and External
Controls
Connecting the Room Thermostat /
The appliance is designed to be connected to a volt free room
thermostat. Connect the cable to terminal blocks No. 1 and 2.
Connecting the Weather Compensation
Sensor
The appliance is designed to be connected to an outdoor
weather compensating temperature sensor. Connect the cable
to terminal blocks No. 5 and 6.
3,4
:
Tank
Storage Thermostat
9
:
P.E
10
:
Neutral
11
:
Live
12
:
EXT.
3-WAY
[
CH
]
13 :
EXT.
3-WAY
[ DHW ]
14 :
EXT.
3-WAY
[ COM ]
9
10
11
12
13
14
1
2
3
4
5
6
1,2
:
Room
Thermostat
/
Room
Controller
5,6
:
Outdoor
Temperature
Sensor
DIP Switch Settings
14.5
The dip switches are on the top of the control panel as shown on
the diagram.
Refer to the following table to ensure that the dip switches are
properly set to the correct position depending on boiler type
Switch No.
Function
ON
OFF
1
-
-
2
Maximum operation
Normal operation
3
Minimum operation
Normal operation
4
LPG(G30)
-
5
-
-
6
-
-
7
Natural Gas
-
8-10
Heat Capacity
Switch No.
Heat Capacity
21K(A)
25K(A)
32K(A)
37K(A)
8
OFF
OFF
OFF
ON
9
ON
ON
OFF
OFF
10
ON
OFF
ON
OFF
1 2 3 4 5 6 7 8 9 10
ON
OFF
Programmable Room Stat
i,e LPG or Natural Gas. Note: All boilers are pre-set to Natural Gas