EGT EGT-300 Скачать руководство пользователя страница 16

16

Check out before requesting help and reporting product failure.
Before calling customer’s support, check the following and if you still need help     
please contact customer support.

Trouble Shooting Chart

Symptoms

Causes

Measures to Be Taken

Significantly less water

comes out

Cold water shut o

ff

 valve 

not fully open

Power adapter not fully
installed

Power adapter not fully
installed

Damaged Blue LED 

Fitting and parts are not 

firmly connected

Filter life is ended or filter 

is clogged

No lights in the 
display

Significantly less

Hydrogen Rich water
comes out

Water leaks from 
machine

Bubble in the water 

Strange working 
sound

Water tastes and smell
 strange

• Make sure all shut o

ff

 valves are fully

  opened

• Replace the filter

• Replace filter

• Shut o

ff

 adapter valve and unplugged.

  Contact your dealer or customer support

Filter life is ended or filter 

is clogged

Filter life is ended or filter 

is clogged

Long term unused

If water pressure is low

• Is not crimped or bent

• Make sure power adapter is fully installed
  in back of electronic module and plug is 
  completely installed in outlet
• It is broken. Contact your dealer or
  customer support. Without led light, 
  water still comes out from spigot

• Make sure power adapter is fully installed
  in back of electronic module and plug is 
  completely installed in outlet

• Shut o

ff

 adapter valve and unplugged.

  Refer to replace filter and open side panel,

  Check the leakage point

•  Shut o

ff

 adapter valve and 

contact 

  your dealer or customer support

Filter is not sealed properly

Hydrogen Bubble

• Check where the filter is installed and

  contact your dealer or customer support

• Will disappear soon

Less drain water when First
time use

Operating sound, Hydrogen
generating sound

• Drain 10 liters out from machine

• This is normal

• Replace the filter or drain 10 liters out 

  from machine

If water comes out  from 
O  outlet hole

2

Содержание EGT-300

Страница 1: ...of each part Product configuration How to install before use Installation overview How operate the system How to replace filter How to remove remained electrolytic water Filter configuration Trouble s...

Страница 2: ...oncentration is always provided by controlling generation of hydrogen dissolution timing concentration control of hydrogen water etc At present regular concentration of hydrogen DH based on sample dev...

Страница 3: ...se read it carefully and follow the instructions to avoid a hazard that may occur When using your appliance always follow basic precautions including the following Warning Caution WARNING Do not attem...

Страница 4: ...exposed to water or moisture other heating system If the main body falls in the water or water leak from inside of cabinet immediately disconnect the plug and then take it out of water When the unit...

Страница 5: ...5 1 1 2 3 4 5 2 3 4 5 6 6 7 7 8 8 Middle valve Feed Water Supply 9 9 Side Panel Fixing Screw Power Supply Water Spigot Water Lever Side Panel Drip Tray Grill Drip Tray Name of each part...

Страница 6: ...ucture 1 2 3 4 5 6 7 8 9 10 Hydrogen Generator Module Device Hydrogen Generator Module Drain Cap LED Light Drip Tray Water Spigot Carbon Filter UF Membrane Filter PCB Cover Pressure Regulator Reducer...

Страница 7: ...nce or reduce water ow When connecting to water bottle x it so that the water supply tube is immersed in the bottled water bottle Notice After nishing installation please run about 2 liters of the wat...

Страница 8: ...it in a place it may not be adversely affected by temperature sunlight dust salt sulfur content etc Under Sink Type A typical connection using the included adapter valve is shown in the illustration...

Страница 9: ...ing to the water lter inlet of the adaptor value Turn on the middle valve for inlet water Turn on the water supply valve You are now ready to turn the water main back on As the system lls check for le...

Страница 10: ...rd or it may damage related parts install the other end of the tubing from the inlet side of the manifold of the feed water adapter Insert plastic tab to ensure quick connect tting cannot come undone...

Страница 11: ...the xture Place washer and lock washer and xing nut onto the mounting bolt Position tube outlet deco on xture then tighten nut securely Insert standard tube Mounting surface 1 2 3 4 5 6 7 5 Washer 37...

Страница 12: ...12 How to operate the system How to use When push dispensing water lever to machine Water comes out from water spigot When leave the dispensing lever water will not come out to water spigot Push...

Страница 13: ...unit and slide the right hand panel to open cover Turn the cartridge to the left counterclockwise and pull the cartridge straight down to remove it Insert new cartridge and turn right Align the cover...

Страница 14: ...use the product for a long time be sure to remove any water remaining in the electrolyzer Storing electrolyzer for a long period without removing water may contaminate the inside of the electrolyzer...

Страница 15: ...Water Housing material Filter component Capacity Liter Gallon Dimension Weight polypropylene 1 800L 475 gallon 3 600L 951 gallon 67 203 H Pre Carbon Filter Filtration Carbon Block 270g 6lb UF Membrane...

Страница 16: ...er life is ended or lter is clogged Filter life is ended or lter is clogged Long term unused If water pressure is low Is not crimped or bent Make sure power adapter is fully installed in back of elect...

Страница 17: ...si Temperature Limit 119 mm W x 363 mm D x 340 mm H 4 7 inch W x 14 3 inch D x 13 5 inch H 4 5 Kg 9lbs 5 40 41 F 104 F Hydrogen Rich water Puri er Model 119 mm 363 mm 340 mm Power Requirement Volt Pow...

Страница 18: ...Memo 18...

Страница 19: ...Memo 19...

Страница 20: ...ge caused by intention or negligence of the consumer Failure caused by repair or alteration at a place other than our service center or retail store Failure due to abnormal power supply or faulty of c...

Отзывы: