10
• Installation Overview
①
Measure 3/4” from the ends of tubing ( inlet end) and mark with a pencil.
( Check for roundness, smoothness, cut, nicks, flat spots, and sharp edges.)
②
③
Push the tubing firmly into each fitting on the manifold until the line is flush with the Fitting collar.
(If the tubing is removed, re-cut the end, measure, mark and re-insert).
The tubing must be fully inserted to avoid leaks
(To remove tubing, depress and hold white collet; pull tubing out to remove).
④
Pull out slightly on tubing to ensure a good seal. Do no pull too hard or it may damage related parts.
⑤
install the other end of the tubing from the inlet side of the manifold of the feed water adapter.
Insert plastic tab to ensure quick- connect fitting cannot come undone.
⑥
①
②
Remove plastic tab from fitting.
Push the collet inward and hold with a finger while pulling the tubing out.
Make sure the collet is pushed evenly on all sides. If only one side is pushed, the tubing
will not be removable.
Making Tubing Connections (Tubing is not performance - tested or certified by NSF)
To Disconnect Tubing :
CORRECT
INCORRECT
collet (depress to remove tubing)
tubing
Tubing correctly cut and connected
end of tubing round and smooth.
with no cuts, nicks or flat spots
Incorrect partial engagement
correct full 3/4”
Содержание EGT-300
Страница 18: ...Memo 18...
Страница 19: ...Memo 19...