47
- Input Scope (Automobile signal): ≥10V in forward impulse; Bandwidth ≥0.5mS
- Input Scope (Normal signal): ≥100mV; when ≥100Hz: ≥200mV.
J. Duty Cycle
Range
Resolution
Accuracy
1%~90%
0.1%
Automobile signal (input scope
≥10V): (4%+5)
10%~90%
Normal signal (input scope
≥500mV): reference only.
K. Dwell Testing
Range
Resolution
Accuracy
Overload
Protection
4CYL
0.1º
±(3%+5)
600 Vp
6CYL
8CYL
Remark
:
- Input Scope: ≥10V in forward impulse; Bandwidth ≥0.5mS
L. TACH (ROTATION SPEED) TESTING
Range
Resolution
Accuracy
Overload
Protection
4CYL
10 RPM
±(3%+5)
600 Vp
6CYL
8CYL
Remark
:
- Input Scope: ≥10V in forward impulse; Bandwidth ≥0.5mS
- Maximum Tach: 10000 RPM, Tach = Displayed Reading x 10.
MAINTENANCE
This section provides basic maintenance information including battery and fuse replacement
instruction.
Warning!
Do not attempt to repair or service your Meter unless you are qualified to do so and have the
relevant calibration, performance test, and service information.