background image

 
 

 

13B

7.

 

DMX

 

512

 

Connection

   

The

 

DMX512

 

is

 

widely

 

used

 

in

 

intelligent

 

lighting

 

control,

 

with

 

a

 

maximum

 

of

 

512

 

channels.

   

 

 

1.

 

Connect

 

the

 

fixture

 

together

 

in

 

a

 

“daisy

 

chain”

 

with

 

the

 

XLR

 

plug

 

cable

 

from

 

the

 

output

 

of

 

the

 

fixture

 

to

 

the

 

input

 

of

 

the

 

next

 

fixture.

 

The

 

cable

 

cannot

 

be

 

branched

 

or

 

split

 

to

 

a

 

“Y”

 

cable.

 

Inadequate

 

or

 

damaged

 

cables,

 

bad

 

solder

 

joints

 

or

 

corroded

 

connectors

 

can

 

easily

 

distort

 

the

 

signal

 

and

 

shut

 

down

 

the

 

system

 

2.

 

The

 

DMX

 

output

 

and

 

input

 

connectors

 

pass

through

 

to

 

maintain

 

the

 

DMX

 

circuit

 

when

 

one

 

of

 

the

 

units’

 

power

 

is

 

disconnected.

 

3.

 

At

 

last

 

fixture,

 

the

 

DMX

 

cable

 

has

 

to

 

be

 

terminated

 

with

 

a

 

terminator

 

to

 

reduce

 

signal

 

errors.

 

Solder

 

a

 

120

ohm

 

1/4W

 

resistor

 

between

 

pin

 

2(DMX

)

 

and

 

pin

 

3(DMX+)

 

into

 

a

 

3

pin

 

XLR

plug

 

and

 

plug

 

it

 

in

 

the

 

DMX

output

 

of

 

the

 

last

 

fixture.

 

4.

 

Each

 

lighting

 

fixture

 

needs

 

to

 

have

 

an

 

address

 

set

 

to

 

receive

 

the

 

data

 

sent

 

by

 

the

 

controller.

 

The

 

address

 

number

 

is

 

between

 

0

511

 

(usually

 

0

 

&

 

1

 

are

 

equal

 

to

 

1).

 

5.

 

3

 

pin

 

XLR:

 

Pin

 

1:

 

GND,

 

Pin

 

2:

 

Negative

 

signal

 

(

),

 

Pin

 

3:

 

Positive

 

signal

 

(+)

   

5

 

pin

 

XLR:

 

Pin

 

1:

 

GND,

 

Pin

 

2:

 

Negative

 

signal

 

(

),

 

Pin

 

3:

 

Positive

 

signal

 

(+),

 

 

Pin4/5:

 

not

 

used.

 

 

Содержание ILED-7TC

Страница 1: ...LED Panel 7TC ILED 7TC PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE USE USER GUIDE...

Страница 2: ...How to Set the Fixture 4 4 1 Control Panel 4 4 2Main Function 5 5 How to Control the Unit 10 A Universal DMX controller 10 B Master Slave operation 11 C Easy Controller by CA 8 11 6 DMX 512 Configura...

Страница 3: ...stop using the fixture immediately Never try to repair the fixture by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical...

Страница 4: ...ey are visibly damaged Caution There are no user serviceable parts inside the fixture Do not open the housing or attempt any repairs yourself In the unlikely situation your unit may require service pl...

Страница 5: ...o always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture The equipment must be fixed by professionals And it must be fixed at a place where is out of th...

Страница 6: ...o input DMX signal 14 Mains input Connect to supply mains power 15 Mains output Connect to supply mains power for the next unit 4 2Main Function To select any of the given functions press the MENU but...

Страница 7: ...6B...

Страница 8: ...n to the main functions without any change after 8 seconds To go back to the functions without any change press the MENU button again Show Mode Press the MENU button up to when the is shown on the dis...

Страница 9: ...play Pressing ENTER button and the display will blink Use DOWN and UP button to select the sound control on or sound control off Once the mode has been selected press the ENTER button to setup or auto...

Страница 10: ...NTER button to setup or automatically return to the main functions without any change after 8 seconds To go back to the functions without any change press the MENU button again Display Inversion It is...

Страница 11: ...To go back to the functions press the MENU button again Software version Press the MENU button up to when the is blinking on the display Pressing ENTER button and the display will show the version of...

Страница 12: ...t as a Master or as a Slave C Easy Controller by CA 8 The easy remote control is used only in master slave mode There is a terminator for connect the easy controller inside the fixture By connecting t...

Страница 13: ...12B 6 DMX 512 Configuration 4 Channels Mode...

Страница 14: ...and input connectors pass through to maintain the DMX circuit when one of the units power is disconnected 3 At last fixture the DMX cable has to be terminated with a terminator to reduce signal error...

Страница 15: ...or on PCB of the fixture or the previous one 4 Try to use another DMX controller 5 Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to DM...

Страница 16: ...e environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the fixture s optics y Clean with soft cloth using normal glass clean...

Страница 17: ...e with the provision of the Electromagnetic Compatibility EMC Directive 2004 108 EC EN55103 1 2009 EN55103 2 2009 EN61000 3 2 2006 A1 2009 A2 2009 EN61000 3 3 2008 Harmonized Standard EN 60598 1 2008...

Страница 18: ...the right to change specifications without prior notification Images are representing but not necessarily a precise product reference EFX shall be under no liability for any loss damage or injury for...

Отзывы: