![EFILive CM2350B Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/efilive/cm2350b/cm2350b_user-manual_2367329011.webp)
Cummins 6.7L CM2350B CSP5
User
Guide
- 9 -
www.efilive.com
11. Navigate to [F5: Edit] and expand the EFILive Custom Calibrations folder.
12. EFILive automatically populates the new CSP
5
tables with factory values during
the upgrade. On modified engines these may not be suitable settings, so you
may need to copy your own tables in to the new CSP
5
section(s).
Program #1 to Program #3 have factory values inserted into the maps. Program
#4 contains the values from the standard OS maps prior to the CSP
5
conversion.
13. Edit the values on your individual tunes, and [Save] the changes to your tune file.
14. Flash the CSP
5
tune into your ECM. Refer to pass-thru flashing, FlashScan
V3/AutoCal V3 flashing or FlashScan V2 flashing for further instructions.
Tune Switch Password
Users may restrict tune selection by adding a password to move between tune
selections to prevent unauthorized switching between tunes 1 to 5.
Before switching between tune selections, users would need to enter in the
password (1 to 9999). If the password is correct, the tune will switch, if it is
incorrect the tune will not switch.
It should be noted that not all switching devices may support this function,
however EFILive's own FlashScan and AutoCal hardware does.
To enable the tune switch password, users need to input their chosen password in
the calibration. As the calibration description states, if the password = 0 then there
is no password prompt given to the user when switching tunes.