3. Lithium battery communication configuration 
 
ADD Switch: 

There are 4 ADD switches are to define different baud rate and battery group 

address. If switch position is turned to bottom for “OFF” position, it means “0”. If switch 
position is turned to upper for “ON” position, it means “1”.

   

 

 

 

 

Dip 1 must be set to "ON" (baud rate 9600).   

 

Dip 2, 3 and 4 are used to set up the battery group address. Further information can be 

found in the manual for the Pylontech US 2000 lithium battery. 

 

Note:   
 

 

Only the AX M1 4000/5000-48 and AX K1 4000/5000-48 inverter with the firmware 
version xx.40 or higher can communicate with Pylontech batteries via the AX Li Com-
Box. 

 

If there is more than one battery group, the HV device (hub) is also required. In this 
case  the  AX  Li  COM  Box  must  be  connected  to  the  Hub  instead  of  the  batterie 
(Pylontech manual, page 37). 
 

 