39
5
823
1
10a
9
Standard Installation
1. Position the unit no closer than the minimum clearances to combustible
materials. Check that no overhead cross members in the ceiling or roof will be
cut. Reposition unit if necessary, being careful not to move closer than the
minimum clearances.
2. A non-combustible floor protector (hearth extension) must be installed under
the unit. The floor protector must extend a minimum of 16 inches (450 mm)
beyond the front and side doors and 8 inches (200 mm) beyond the left side.
The floor protector must be equivalent to 1/2 inch (9.5mm) with a k factor of at
least 0.84 Btu/inch°F
Determining Thickness Requirements of Alternate Floor Protection Materials
The following formula gives the means of determining thickness of alternate
materials:
k of the alternate material x thickness of
=
thickness of
k of the specified material
specified material
alternate material
For example common brick has a k value of 5.0. The following would
determine the thickness necessary:
5.0 x
1/2 inch
=
3.0 inches of common brick
0.84
3. Mark the position of the required floor protector on the floor. Remove the unit
and install the floor protector.
4. Position the unit on the floor protector at the proper clearances.
5. Install a 6-inch diameter, minimum 24 MSG black or 26 MSG blued steel
connector pipe on the flue collar of the unit.
•
The stove is NOT to be connected to any air distribution duct or system.
•
A chimney connector shall not pass through an attic or roof space,
closet or similar concealed space, or a floor, or ceiling. Where passage
through a wall or partition of combustible construction is desired, the
installation shall conform to CAN/CSA-B365, Installation Code for Solid-
Fuel-Burning Appliances and Equipment. (Canadian installations only )
6. Use a chimney connector adapter to connect the chimney connector up to the
chimney. The small ends of the chimney connector should all point down for a
drip free installation. Position all seams toward the back for aesthetics. The
chimney connector must be 6-inch diameter.