7 / Adjusting the Spray

Adjusting the Spray

1. Turn the nozzle air pressure on the

controller to zero. Using the nee-
dle stroke control knob 

on the

781S valve, set the fluid flow rate
to one or two drops per second.
Check flow rate by actuating the
controller in the time override
mode. Make valve stroke adjust-
ments when the controller is off.

2. Set the nozzle air pressure on the

controller to 10 psi (0.7 bar) and
actuate the controller. The valve
will produce a fine spray.

3. To change fluid flow, use the 

needle stroke control knob 

,

and/or tank air pressure.

Note:

Avoid tight stroke settings with high

tank pressure.

4. To change nozzle air, use the nozzle

air pressure regulator 

. Higher

pressures will provide finer spray.

To Make Timed Deposits

1. Return to the time control by press-

ing the time override button 

. The

display should show the time setting.  

2. Adjust the deposit time to 0.5 sec-

onds by using the time set 

and

decimal

buttons.

3. Press the cycle button 

. The con-

troller will open the valve for 0.5 sec-
onds. Adjust time and test deposits
until desired output is obtained.

VALVEMATE 
7040

Note:

Optimal results will be obtained

with the proper combination of time 
setting, needle stroke control knob, 
and reservoir and nozzle air pressure.

Содержание ValveMate 7040

Страница 1: ...VALVEMATE 7040 Electronic pdf files of EFD manuals are also available at www efd inc com manuals html ValveMate 7040 Controller Operating Manual A NORDSON COMPANY...

Страница 2: ...y exceed the purchase price of the equipment This warranty is valid only when oil free clean dry filtered air is used EFD makes no warranty of merchantability or fitness for a particular purpose In no...

Страница 3: ...ions 2 Operating Features 3 Typical Setup 4 Setup 5 6 Adjusting the Spray 7 Programming Nozzle Air Delay 8 Schematic and Replacement Parts 9 Troubleshooting Guide 10 Input Output Connections 11 12 Con...

Страница 4: ...kg 3 1 lb Cabinet Aluminum Input Voltage Selectable 100 120 220 VAC Internal Voltage 24 VDC Feedback Circuits 5 to 24 VDC NC solid state switch 250mA maximum Initiate Circuit 5 to 24 VDC signal or con...

Страница 5: ...999 to 9 99 or 99 9 Decimal does not appear in the display while in the 999 second range Operating Features 4 Program Press to clear display to zeros Display flashes bright dim while in program mode P...

Страница 6: ...es fail safe air pressure release during cap removal Typical Setup 7543BP for 1 4 OD tube 7610BP for 3 8 OD tube LVLP spray valve Plant air 70 psi 4 8 bar minimum Material Constant air Pulsed air for...

Страница 7: ...00PMK Input Power 1 View cartridge window in power cord receptacle to ensure that the voltage is set properly Selections are 100 120 or 220 VAC 2 If it does not match remove the fuse cartridge Then re...

Страница 8: ...ng The quick connect on the air tee is used to provide air pressure to the air pressure regulator on EFD tank reser voirs This connection will be made during valve installation 3 Remove the cap plug f...

Страница 9: ...ntrol knob and or tank air pressure Note Avoid tight stroke settings with high tank pressure 4 To change nozzle air use the nozzle air pressure regulator Higher pressures will provide finer spray To M...

Страница 10: ...power switch on 3 The display will read SEL select Release the time override button 4 Press either the up or down time set buttons once and release The current nozzle air delay setting will be display...

Страница 11: ...ly 7 2001A Gauge 0 to 30 psi 0 to 2 07 bar 8 2004B Female quick connect black hidden from view below item 9 9 2004B W Female quick connect white 10 2024 160 1 4 OD x 160 ID tubing 11 2081A Air input q...

Страница 12: ...input voltage Ensure that the external voltage to the circuit is between 5 and 24 VDC and that the load does not exceed 250mA If the circuit has been overloaded the fuse may have blown Replace fuse i...

Страница 13: ...le an open collector circuit closes and remains closed until the next dispense cycle This circuit can be utilized to signal back to a host computer start another device in sequence or other operations...

Страница 14: ...12 VA 5 VDC Solenoid 1 7815 control Protector Solenoid 2 atomizer control Power supply Nonvolatile memory Programmable display Opto coupler 24 VDC Mechanical Contact Initiate Mechanical contact power...

Страница 15: ...h each controller that is connected The initiate power supply should be sized accordingly 2 End of Cycle Feedback Circuit This circuit will ensure that the end of cycle signal will come from the last...

Отзывы: