26
27
Figure 11
Figure 12
Figure 13
Figure 13
7.7 Display
Only in english language setup!!!
This function, when enabled, will show all Menus with a
larger font.
7.8 Startup Clean
If selected, the splicer will do a clean electrodes every
time the splicer is turned on if the lid is closed and there
are no fibers in the camera view.
7.9 Splice Pause
If selected, the splice will pause and wait for a button to
be pressed, when the fibers are in position for splicing.
7.10 Exit
Exit the Menu.
8. Prepairing the fibers and place them in
the INFRALAN® Splicer
Often, incorrect handling or preparation causes splice
loss. It is crucial to keep tools and fiber clean; the inves-
ted time used in fiber and tool handling is more than
compensated for in reduced troubleshooting effort.
8.1 Don’t forget the protective sleeve
Before prepairing the fiber for splicing, make sure to put
the protective sleeve in place.
8.2 Place the fiber in the fiber holders
Place the 250µ fiber in the black holder, 900µ fiber/pig-
tail in the blue holders. The fiber should „stick out“ for
approx.3-4cm
7.4 Language
Set the language by stepping up/down with the small buttons. Press the large button (SELECT)
for choosing a new language (or go to the top and select EXIT).
7.5 Fiber Position
Calibrate fiber position when replacing cleaver (and/or if the fibers –for any reason- are not in the
correct position when placed in the V-groove). Put fibers in their holders and place them in the
splicer before starting. Start automatic calibration of fiber zero point setting by pressing the
large button (SELECT).
If the fibers are visible and in the correct position like in
the picture below then this new position shall be saved.
7.6 Electrodes
Use this function to reset the splice counter when the
electrodes have been replaced. The electrodes are made
to last for 2000-2200 splices.
Figure 9
Figure 10