![EEG EN 530 Скачать руководство пользователя страница 28](http://html.mh-extra.com/html/eeg/en-530/en-530_instruction-manual_2366479028.webp)
EN530 HDTV Smart Encoder IV
The EN530 is shipped with a cable adapter marked 2X3. This is a 3 wire
RS232 adapter cable that converts a modular serial port connector to a female
DB9 connector. This adapter may be connected directly to a standard PC serial
port. If a longer cable is required, a 9-pin, three wire straight serial cable
should be used. A “null modem” cable MAY NOT be used for this purpose
since it will reverse the connections of pins 1 and 2. This adapter cable cannot
be used with a data port that is configured for RS422 operation. The pin
assignment of the DB9 connector of the adapter cable is shown below:
Pin DB9
Adapter
1
2 Tx
3 Rx
4
5 Ground
6-9
GPI Switch Functions
Each GPI Switch is activated when connected to ground, and inactive when
open, or left floating. The four default GPI functions are defined as follows:
Switch 1: Force 608 Up-conversion
Activating this function causes upconverted 608 caption data from the SD
video input to be encoded onto the HD video outputs, even in the presence of
upstream captioning on the HD input. Locally input data will still override the
upstream 608 data, but all upstream VANC caption data will be ignored.
Switch 2: Modem Lockout
Activating this function disables the modem for data input. The modem will
still answer calls, but users will not be able to enter caption data. If a modem
user is entering data, and then this switch is closed, the modem user will be
booted out of data input mode.
Switch 3: Port 2 Lockout
Activating this function disables P2 for data input. Users connected to P2 will
not be able to enter any caption data, and if a user is inputting data and then the
switch is closed, the user will be booted out of data input mode.
©2000-2007 EEG Enterprises, Inc.
27