DE285 HD Caption Decoder/VANC Monitor
5.8.3.
Alarm Settings
The Alarm Settings subsection allows the user to set a value in seconds
that captions can be missing for before a GPIO alarm is triggered on pin
1. To change this value, enter a new value into the text field and click the
Apply
button to update the No Captions Timeout. If you would like to
see this alarm on the logging section of the website you must set the ’No
Captions’ alarm by going to the Logging tab, clicking on the
Logging
Options
button and selecting the ’No Captions’ checkbox.
5.8.4.
VANC Settings
The VANC Settings subsection provides a way to enable or disable pass-
ing VANC data through the box on the outputs. This option will prevent
other decoders from double decoding the VANC on the video feed after
the DE285.
5.8.5.
Log Settings
The lower part of the Settings tab is the Log Settings subsection, which
provides a way to set the date, time and time zone for accurate trigger
and alarm logging. The current date, time, and timezone can be seen to
the right of the
Set Date/Time
button. To change the Date/Time, sim-
ply use the dropdown menus to select the month, day and year and then
set the local time and time zone that you are in. Alternatively, you can
set the date and time by clicking on the
Copy Computer’s Date/Time
button, which uses the date and time from your current machine to set
the date and time. When using this option be aware that the timezone is
not copied along with the date and time information. To confirm the set-
tings, click the
Set Date/Time
button at the bottom of the Log Settings
section. The triggers and alarms will now have the correct timestamp
when viewed in the Logging module.
38
Copyright ©2009-2011 EEG Enterprises, Inc.
All rights reserved.