CE Declaration of Conformity
P2
00
00
54
0M
The following product
AXXX -
YY
-
ZZZ
Pump type
Variant
Motor description
XXX
YY
ZZZ
652 = RV3
01 to 99
903 = 220/240V 50/60Hz Single Phase
653 = RV5
904 = 100/200V 50/60Hz Single Phase
654 = RV8
905 = 200-230/380-460V 50/60Hz Three Phase
655 = RV12
906 = 110-115/120V 50/60Hz Single Phase
925 = 200-230V 50/60Hz Three Phase
Is in conformity with the relevant requirements of European CE legislation:
2006/42/EC
Machinery directive
2014/34/EU
ATEX directive on use in potentially explosive atmospheres.
Intertek Testing and Certification Limited, 0359
Intertek House, Cleeve Road, Leatherhead, Surrey, KT22 7SB
ATEX marking:
II 3 G Ex h IIB T4 Gc
INTERNAL ATMOSPHERES ONLY
TCF 218
2011/65/EU
Restriction of certain hazardous substances (RoHS) directive
as amended by Delegated Directive (EU) 2015/863
Based on the
relevant
requirements of harmonised standards:
EN 1012-2:1996 +A1:2009 Compressors and vacuum pumps. Safety requirements. Vacuum pumps
EN 61010-1:2010 *
Safety requirements for electrical equipment for measurement, control and laboratory
use. General requirements
*
1-phase pumps only
The pumps comply with EN 61010-1 when installed in accordance with the instruction
manual supplied with the pumps.
EN ISO 80079-36:2016
Explosive atmospheres – Part 36: Non-electrical equipment for explosive atmospheres.
Basic method and requirements
EN ISO 80079-37:2016
Explosive atmospheres - Part 37: Non-electrical equipment for explosive atmospheres --
Non-electrical type of protection constructional safety ''c'', control of ignition sources
''b'', liquid immersion ''k''
Edwards Ltd
Innovation Drive
Burgess Hill
West Sussex
RH15 9TW
UK
Содержание RV12