HIGH THROUGHPUT MODE
S
Parameter
Units
RV8
RV12
1-phase
3-phase
1-phase
3-phase
Gas-ballast flow
l min
-1
16
16
Maximum water vapour pump-
ing rate
kg h
-1
0.22
0.20
0.29
0.25
Maximum water vapour inlet
pressure
mbar
38
34
32
28
Pa
3.8 x 10
3
3.4 x 10
3
3.2 x 10
3
2.8 x 10
3
Table 7
Performance characteristics
MODE SE-
LECTOR
POSITION
GAS BALLAST CONTROL
Closed (position ‘0’)
Low flow (position ‘I’)
High flow (position ‘II’)
High Vac-
uum mode
S
Ultimate total pressure
Ultimate total pressure
Ultimate total pressure
mbar
Pa
mbar
Pa
mbar
Pa
2 x 10
-3
2 x 10
-1
3 x 10
-2
3
1.2 x 10
-1
(RV3)
1.0 x 10
-1
(RV5)
6 x 10
-2
(RV8/12)
1.2 x 10
1
(RV3)
1.0 x 10
1
(RV5)
6.0 (RV8/12)
Use for the best ultimate
pressure
Maximum water vapour
pumping rate
Maximum water vapour pump-
ing rate
1-phase
pumps
3-phase
pumps
1-phase pumps 3-phase pumps
0.06 kg h
-1
0.04 kg h
-1
0.22 kg h
-1
(RV3/5/8)
0.29 kg h
-1
(RV12)
0.12 kg h
-1
(RV3/5)
0.20 kg h
-1
(RV8)
0.25 kg h
-1
(RV12)
03/2021 - ©Edwards Limited
Page 17
A65201880_AA
A65201880_AA - Technical data