7.3 Reset the service interval using a nST PC program
The nST PC program is PC-based software that can be used with the nEXT pump, either
via the serial interface or via the USB service port.
This software is available from www.upgrades.edwardsvacuum.com.
Currently, nST software requires a free license to be used. To obtain a free license follow
the on screen instructions, fill out the user data form and then send the automatically
generated email to Edwards.
First time users are recommended to refer to the nST Support Toolkit instruction manual
D396-49-880.
To confirm that the service reset has been successful, check that the status LED has been
reset and is no longer flashing. Once the service counter reset has been completed, a
power cycle must be performed to complete the process.
7.4 Reset the service interval using the turbo drive standby speed
control buttons
▪
Ensure the drive is powered. Using a suitable tool, e.g. the reset tool, press and
hold the increase and decrease standby speed buttons simultaneously for more
than 5 seconds.
▪
To confirm that the service reset has been successful, check that the status LED has
been reset and is no longer flashing. Once the service counter reset has been
completed a power cycle must be performed to complete the process.
Figure 26 Use the reset tool
2
1
1. Use to reset the service counter
2. Use to operate the standby increase or
decrease button
1. Use to reset the service counter
2. Use to operate the standby increase or
decrease button
06/2021 - ©Edwards Limited
Page 29
300872820_002_C2
B8J203880_C
300872820_002_C2 - Service counter reset