Edwards HP20T Скачать руководство пользователя страница 13

Hydraulic Power

Your Edwards Horizontal Press is factory assembled and tested for opti-
mum performance when powered by Edwards Manufacturing Company 
rated hydraulic power supplies.

The Horizontal Press is powered by either an Edwards Ironworker with 
the factory installed Hydraulic Accessory Control Package or an Edwards 
Porta-Power, 5hp, 3000psi, portable power unit. 

ALTERNATE POWER SOURCES ARE NOT RECOMMENDED 
AND MAY COMPROMISE MACHINE OPERATION, MACHINE 
HYDRAULIC WARRANTY AND OPERATOR SAFETY.

 

Follow electrical connection installation instructions for power supply as 
set forth within the Installation Manual of the Edwards Ironworker or 
Porta-Power.

Powering with an Edwards Ironworker

Power selection controls are located adjacent to the starter on the feed 
side of the machine. Hydraulic quick connections and accessory controls 
are located on the drop-off side or end cap of the machine. 

With the Ironworker power off, install Horizontal Press hoses, power and 
control. 

Assure your M12 connections are seated properly. Align 

M12 male and female 

fi

 ttings so that keyed surfaces align. Mis-

alignment of surfaces will prohibit correct operation.

•  Install the Horizontal Press male and female accessory hydraulic 

hoses to the ironworker male and female quick-connect hydraulic 

fi

 ttings. Both 

fi

 ttings have a detent ball setting that must be aligned 

to couple and uncouple hoses.

•  Remove the safety cap at the push button port. Attach the Horizontal 

Press hand control male mil. spec. control cable to the female mil. 
spec. accessory control port at your Ironworkers Hydraulic Ac-
cessory package. Attach the yellow limit switch cable to the limit 
switch port of the ironworker. Attach the yellow Auxiliary cable to 
the Aux Light port on the ironworker. 

With all Ironworker and Horizontal Press stations clear of hands, 
tools, tooling, material or debris, power up the Ironworker by de-
pressing the green button on the starter box.

With the power on, your Ironworker machine will return to a neutral 
position.

Turn the 3-position switch on the front of the machine case to the Ac-
cessory position. This operation disables the Ironworker and switches 
control to the accessory hand control. 

Test the Horizontal Press operation by depressing the OUT control but-
ton. Once depressed, the cylinder will extend. Releasing pressure on the 
OUT control button will stop the cylinder. Test the Horizontal Press opera-
tion by depressing the IN control button. Once depressed, the cylinder 

will be retracted back into the cylinder enclosure. Releasing pressure on 
the IN control button will stop the cylinder.

Test the digital encoder and limit switches by rotating the scale hand 
crank.

Depress the red e-stop button to kill power at the Ironworker. To reset 
power, twist the e-stop button and push start button at the Ironworker.

When disconnecting your Horizontal press, simply reverse procedure. 

Replace the safety cap at the push button port to restore power to 
your Ironworker.

Powering with an Edwards Porta-Power

Your Edwards Porta-Power  5hp / 3000psi / Portable Power Unit will 
power all your Edwards Hydraulic Accessories. 

Follow electrical connection installation instructions as set forth within 
these sections of the Installation Manual:

With the Edwards Porta-Power off, install accessory hoses, power and 
control. 

Assure your M12 connections are seated properly. Align 

M12 male and female 

fi

 ttings so that keyed surfaces align. Mis-

alignment of surfaces will prohibit correct operation.

•  Install the male and female Horizontal Press hydraulic hoses to 

the Porta-Power male and female quick connect hydraulic 

fi

 ttings 

adjacent to the starterbox.  Both 

fi

 ttings have a detent ball setting 

that must be aligned to couple and uncouple hoses.

• 

Remove the safety cap at the push button port. Attach the Horizontal 
Press hand control, male mil. spec. control cable to the female 
mil. spec. accessory push button port on the Porta-Power case. 
Attach the yellow limit switch cable to the limit switch port of the 
Porta-Power. Attach the yellow Auxiliary cable to the 24V port on 
the Porta-Power.

With all Ironworker and Horizontal Press stations clear of hands, 
tools, tooling, material or debris, power up the Porta-Power by de-
pressing the green button on the starter box.

With the power on, your Horizontal Press is in a neutral position.

Test the Horizontal Press operation by depressing the OUT control but-
ton. Once depressed, the cylinder will extend. Releasing pressure on the 
OUT control button will stop the cylinder. Test the Horizontal Press opera-
tion by depressing the IN control button. Once depressed, the cylinder 
will be retracted back into the cylinder enclosure. Releasing pressure on 
the IN control button will stop the cylinder.

Test the digital encoder and limit switches by rotating the scale crank.

Depress the red e-stop button on the hand control to kill power at the 
Porta Power. To reset power, twist the e-stop button and push start but-
ton at Porta Power.

When disconnecting your Horizontal press, simply reverse procedure. 

Replace the safety cap at the push button port to restore power to 
your Porta Power.

3

Содержание HP20T

Страница 1: ...Horizontal Press HP20T Safety Instructions Manual EDWARDS 07 2018 Original Instructions HAT6000 2...

Страница 2: ...wards Manu facturing Company Keep all manuals close to the machine to allow for easy reference when necessary Provide operators with sufficient training and education in the basic functions of the mac...

Страница 3: ...abels affixed to the machinery may result in operator death or injury WARNING This product can expose you to chemicals including Methyl Isobutyl Ketone which is known to the State of California to cau...

Страница 4: ...Ironworker Porta Power before servicing Read understand and follow all labels shown on the machine and described in the Safety Instructions Manual Installation Manual Operations Manual Maintenance Ma...

Страница 5: ...3...

Страница 6: ...lothing gloves footwear head gear and hearing protection while operating or servicing this machinery Refer to All Manuals Each manual that comes with this machine contains critical instructions regard...

Страница 7: ...r to a pressing operation Workpiece must be clean and free of substances at the pressing surface that would allow the pressing surfaces to slip under load Workpiece Support Workpiece failure may be a...

Страница 8: ...1107 Sykes St Albert Lea MN 56007 800 373 8206 www edwardsironworkers com S EDWARDS...

Страница 9: ...Horizontal Press HP20T Installation Manual 07 2018 Original Instructions HAT6000 1 EDWARDS...

Страница 10: ...l in any form in whole or in part is not permitted without the written consent of Edwards Manu facturing Company Keep all manuals close to the machine to allow for easy reference when necessary Provid...

Страница 11: ...abels affixed to the machinery may result in operator death or injury WARNING This product can expose you to chemicals including Methyl Isobutyl Ketone which is known to the State of California to cau...

Страница 12: ...d and locked into the safety detent closest to the maximum available fork spread Unpacking Moving the Horizontal Press Your Edwards Horizontal Press includes surface and remotely mounted electrical ca...

Страница 13: ...ressed the cylinder will be retracted back into the cylinder enclosure Releasing pressure on the IN control button will stop the cylinder Test the digital encoder and limit switches by rotating the sc...

Страница 14: ...1107 Sykes St Albert Lea MN 56007 800 373 8206 www edwardsironworkers com S EDWARDS...

Страница 15: ...Horizontal Press HP20T Operations Manual Serial Number 07 2018 Original Instructions HAT6000 3 EDWARDS...

Страница 16: ...ation Signal Word Definition Signal Word Panel Operational Precautions Machine Operations 4 Hydraulic Power Sources Powering with an Edwards Ironworker Powering with an Edwards Porta Power 6 Operation...

Страница 17: ...ulic components are subject to their manufacturer s warranty Edwards Manufacturing Company will within thirty 30 days of date of original purchase proof of purchase required replace F O B the factory...

Страница 18: ...void your machine warranty Never leave a powered machine unattended Turn machinery OFF be fore walking away This machine is manufactured for use by able bodied and able minded operators only Never ope...

Страница 19: ...rd Hydraulic hoses are under pressure Pressurized fluid can pierce skin and cause severe injury To avoid physical hazard always wear personal protective equipment when servicing maintaining the Ironwo...

Страница 20: ...that must be aligned to couple and uncouple hoses Remove the safety cap at the push button port Attach the Horizontal Press hand control male mil spec control cable to the female mil spec accessory co...

Страница 21: ...Attach the yellow limit switch cable to the limit switch port of the Porta Power Attach the yellow Auxiliary cable to the 24V port on the Porta Power With all Ironworker and Horizontal Press stations...

Страница 22: ...Press Operations Diagram Leveling Feet Arbor Crank Arbor Support Universal Tooling Block Scale with Pointer Scale Crank Digital Readout Table Extension Bulk Head Base Cabinet Hydraulic Hoses Tooling...

Страница 23: ...Leveling Feet 7 Table Extension Bulk Head...

Страница 24: ...ire maintenance over time to prevent rust and corrosion The 24 x 42 table may be enlarged by adding table extensions to the table bulkheads located in the base cabinet Hydraulic Cylinder The HP20T is...

Страница 25: ...he gib pins to ensure the ram is parallel to the table surface Press Operation For Operator safety wear personal protective equipment clear the workzoneofanytoolingordebrispriortopoweringthemachineryo...

Страница 26: ...hin the assembly Problem Solution Horizontal Press Inoperable Check accessory control switch Check shop press male 4 pin power cable is connected to female limit switch port Check hand control Mil Spe...

Страница 27: ...Horizontal Press HP20T Maintenance Manual 07 2018 Original Instructions HAT6000 4 EDWARDS...

Страница 28: ...horoughly Keep all manuals close to the machine to allow for easy reference when necessary Provide operators with sufficient training and education in the basic functions of the machine prior to machi...

Страница 29: ...azard always wear personal protective equipment when servicing maintaining the Ironworker Do Not Operate With Guard Removed Physical barriers and guards have been designed and installed to protect mai...

Страница 30: ...ces are fully dry before reconnecting power Maintenance Schedule Your HP20T Horizontal Press will benefit from reasonable care and periodic maintenance Reasonable care includes daily visual observatio...

Отзывы: