background image

B723-00-880

Issue C Original

Instruction Manual

EXPT Pumping Station

Description

Item Number

EXPT Pumping Station

B723-00-000

Содержание EXPT

Страница 1: ...B723 00 880 Issue C Original Instruction Manual EXPT Pumping Station Description Item Number EXPT Pumping Station B723 00 000...

Страница 2: ...This page has been intentionally left blank D of C to be inserted...

Страница 3: ...e EXPT pumping station 12 3 4 Fill the rotary pump with oil 13 3 5 XDS scroll pump silencer 13 3 6 Fit accessories optional 13 3 7 Connect the EXPT pumping station to your vacuum system 14 3 8 Connect...

Страница 4: ...gm pump 15 5 EXPT TIC 23 Tables Table Page 1 EXPT1 pumping station mass 5 2 EXPT2 pumping station mass 5 3 Electrical data 6 4 Operating and storage data 7 5 Fuse ratings 7 6 Earth stud 8 7 Electrical...

Страница 5: ...009 All rights reserved Page iii Edwards and the Edwards logo are trademarks of Edwards Limited Contents B723 00 880 Issue C Associated publications Publication title Publication number EXT Pump Acces...

Страница 6: ...This page has been intentionally left blank B723 00 880 Issue C Page iv Edwards Limited 2009 All rights reserved Edwards and the Edwards logo are trademarks of Edwards Limited...

Страница 7: ...t of Supplementary Publications is provided at the end of the Contents list of this manual A number of these Supplementary Publications will be supplied with your EXPT Pumping Station The Supplementar...

Страница 8: ...n a remote PC and a logic interface for interface with associated system hardware Both systems are base mounted and come in two sizes The EXPT1 base uses robust rubber feet as standard castors are opt...

Страница 9: ...ypical system shown 11 Earth stud 12 Heater supply turbomolecular pump remote use only 13 Backing line valve 14 Flexible bellows 15 Turbomolecular pump 16 TIC controller 17 Castors standard on EXPT2 s...

Страница 10: ...B723 00 880 Issue C Page 4 Edwards Limited 2009 All rights reserved Edwards and the Edwards logo are trademarks of Edwards Limited This page has been intentionally left blank...

Страница 11: ...r to Tables 1 and 2 Electrical data Refer to Table 3 Degree of protection to IEC34 5 1981 IP20 Initial force required to push the EXPT pumping station for systems with castors 3 5 kgf max Table 1 EXPT...

Страница 12: ...a Backing pump TIC controller Supply voltage 50 60 Hz Current A Maximum power kW Full load Start XDD1 100 W 0 355 100 4 67 110 120 4 04 220 240 2 07 200 W 100 6 02 0 49 110 120 5 14 220 240 2 57 E2M0...

Страница 13: ...44 0 825 110 120 10 24 22 375 220 240 5 27 19 27 200 W 100 11 7 45 6 0 96 110 120 11 34 37 54 220 240 5 77 19 77 XDS5 10 100 W 100 10 75 0 575 110 120 9 64 220 240 4 87 200 W 100 12 1 0 71 110 120 10...

Страница 14: ...eference data Earth stud M5 Table 7 Electrical connections General items Reference data Electrical supply refer to Figure 1 item 4 Inlet plug type CEE IEC 320 16 A Backing pump refer to Figure 1 item...

Страница 15: ...dwards Limited Technical data B723 00 880 Issue C Figure 2 Equipment dimensions mm XDD1 and EXT75DX shown Position Base or pump description Dimension A EXPT1 380 0 EXPT2 500 0 B EXT70H ISO63 CF63 415...

Страница 16: ...B723 00 880 Issue C Page 10 Edwards Limited 2009 All rights reserved Edwards and the Edwards logo are trademarks of Edwards Limited This page has been intentionally left blank...

Страница 17: ...ge z Leak test the system after installation and seal any leaks found 3 2 Unpack and inspect Remove the outer cover and all packing materials remove the protective covers from the inlet and outlet por...

Страница 18: ...systems Use slings around the base of the system from front to back make sure each sling is routed between the castors or feet and the base guides to prevent slippage Alternatively use straps with li...

Страница 19: ...or can be ordered as an optional extra To fit the silencer follow the instructions in manual A505 97 880 3 6 Fit accessories optional If you wish to fit accessories to the EXPT Pumping Station fit th...

Страница 20: ...n is supplied with an electrical cable which includes a moulded IEC connector fitted at one end the other end of the cable will be fitted with a moulded plug suitable for connection to the local elect...

Страница 21: ...ctory settings have been changed to provide a standard operation for the EXPT Pumping Station if you replace the TIC Controller you should reconfigure the set up options to suit your application refer...

Страница 22: ...uge cables to each of the three sockets the number indicated above each socket corresponds to the same gauge number shown on the TIC Controller display This option is only available if the EXPT Pumpin...

Страница 23: ...manual for further details of this connector 3 15 Connecting the serial interface The TIC has two serial communications protocols built in RS232 and RS485 RS232 is the simplest interface and can be us...

Страница 24: ...B723 00 880 Issue C Page 18 Edwards Limited 2009 All rights reserved Edwards and the Edwards logo are trademarks of Edwards Limited This page has been intentionally left blank...

Страница 25: ...the EXPT Pumping Station to suit an application refer to the TIC instruction manual 1 Switch on the electrical supply to the EXPT Pumping Station and your exhaust extraction system if available 2 Turn...

Страница 26: ...B723 00 880 Issue C Page 20 Edwards Limited 2009 All rights reserved Edwards and the Edwards logo are trademarks of Edwards Limited This page has been intentionally left blank...

Страница 27: ...als if they are damaged z Dispose of components grease and oil safely refer to Section 6 z Protect sealing faces from damage z Do not touch or inhale the thermal breakdown products of fluoroelastomer...

Страница 28: ...cable 4 Inspect all of the vacuum and exhaust connections and check that they are secure Tighten any loose connections 5 Inspect all of the vacuum and exhaust pipelines and check that they are not cor...

Страница 29: ...the EXPT Pumping Station settings You may need to upload the Pumping Station settings or your personal settings using the TIC PC Monitoring software before you perform a software update Once the upda...

Страница 30: ...B723 00 880 Issue C Page 24 Edwards Limited 2009 All rights reserved Edwards and the Edwards logo are trademarks of Edwards Limited This page has been intentionally left blank...

Страница 31: ...from the vacuum system 3 Drain the oil from the backing pump rotary vane pumps only as described in the instruction manual for the pump Refer to the following documents 4 Place protective covers over...

Страница 32: ...B723 00 880 Issue C Page 26 Edwards Limited 2009 All rights reserved Edwards and the Edwards logo are trademarks of Edwards Limited This page has been intentionally left blank...

Страница 33: ...f the part Fit accessories as described in the Supplementary Publications and in the instruction manual supplied with the accessory 7 2 Spares The spares available for use with the EXPT Pumping Statio...

Страница 34: ...B723 00 880 Issue C Page 28 Edwards Limited 2009 All rights reserved Edwards and the Edwards logo are trademarks of Edwards Limited This page has been intentionally left blank...

Страница 35: ...nections 8 D Description 2 Disposal 25 E Earth stud 8 Electrical connections 8 Electrical data 6 Electrical protection 2 EXPT TIC controller factory default 23 F Fill the rotary pump with oil 13 Fit a...

Страница 36: ...B723 00 880 Issue C Page 30 Edwards Limited 2009 All rights reserved Edwards and the Edwards logo are trademarks of Edwards Limited This page has been intentionally left blank...

Отзывы: