Figure 7 Maximum permissible flange loads
Table 5 Maximum permissible flange load
Maximum force
Pump inlet
Pump outlet
F
X
±892 N
±446 N
F
Y
±1070 N
±356 N
F
Z
±1338 N
±290 N
F
R
±1931 N
±640 N
Maximum moment
Pump inlet
Pump outlet
M
X
±476 Nm
±115 Nm
M
Y
±952 Nm
±231 Nm
M
Z
±721 Nm
±177 Nm
M
R
±1285 Nm
±313 Nm
7.4 Connecting cooling-water
(Only for water cooled version)
1.
Use G1/2 male pipe fittings to fit the cooling-water supply and return hoses.
2.
Remove the blanking plugs from the cooling-water inlet and outlet.
3.
Connect your water return hose to the cooling-water-outlet and connect your water
supply hose to the water-cooling inlet.
4.
Turn on the cooling-water supply.
5.
Inspect the water hoses, pipelines and connections and check that there are no leaks.
Page 27
A41802880_C - Installation