Technical
data
2.3
Mechanical data
2.4
Electrical data: single-phase motor
When you start a cold pump, the motor draws the start-up current shown in
for less than one second. To
prevent unnecessary fuse failure during start-up use a slow-blow fuse. Within five minutes, as the oil in the pump
warms up, the start-up current reduces to the full-load current specified in
2.5
Electrical data: three-phase motors
Refer to the data in
. You can configure the dual voltage motors to operate with either the high range or low
range electrical supply: refer to the diagram specified in
. Dual voltage motors are supplied preset to the
highest of the selectable voltages.
When you start a cold pump, the motor draws the start-up current listed in
for less than one second. Within
five minutes, as the oil in the pump warms up, the current drawn slowly reduces to the full-load current specified in
.
When you restart a hot pump, the motor draws the start-up current specified in
for up to 0.5 seconds. The
current drawn then immediately falls to the full-load current value.
Dimensions
See
(E1M40 and E2M40 pumps) and
(E1M80 and
E2M80 pumps)
Degree of protection (IEC 34-5:1981)
IP55
Pump inlet-port
ISO40 or NW40
Pump outlet-port
25 mm flange, suitable for NW25 fittings
E1M40
E2M40
E1M80
E2M80
Maximum mass (kg)
70.5
72
95
105
Noise level at 1 metre (dB(A))
65
65
70
70
Table 1 - Electrical data (single-phase motor)
Pump
Nominal
supply
(V)
Frequency
(Hz)
Power
(kW)
Full-load
current
(A)
Start-up
current
(A)
Recom-
mended
fuse rating
(A)
Electrical
Supply
Connection
Figure
E1M40
E2M40
240
50
1.1
6.8
40
25
4