A373-10-880 Issue R
Page 6
© Edwards Limited 2012. All rights reserved.
Edwards and the Edwards logo are trademarks of Edwards Limited.
Technical data
2.3
Mechanical data
2.4
Lubrication data
Note:
A Edwards Material Safety Data Sheet for the oils specified below is available on request.
Maximum water vapour pumping rate
0.7 kg h
-1
0.7 kg h
-1
Maximum permitted outlet pressure (for full pump throughout)
0.5 bar gauge
1.5 bar absolute
1.5 x 10
5
Pa
0.5 bar gauge
1.5 bar absolute
1.5 x 10
5
Pa
Table 3 - Mechanical data
Parameter
Reference Data
Approximate pump mass
44 kg
Dimensions
Refer to
Degree of protection
Single-phase motors
IP44
Three-phase motors
IP54
Pump inlet port
NW25 (the flange can be removed from the 1 inch BSP threaded hole)
Pump outlet port
15 mm external diameter nozzle (the nozzle can be removed from the 3/4 inch BSP
threaded hole)
Table 4 - Lubrication data
Hydrocarbon pumps:
Recommended oil
*
*
To operate the pump when the ambient temperature is outside the range specified in
optimise pump performance when you process condensible vapours, you may need a different oil.
Ultragrade 19
Maximum oil capacity
1.32 litres
PFPE - prepared EM pumps:
Recommended oil
Krytox 1506 or Fomblin 06/6
Maximum oil capacity
1.32 litres
Table 2 - Performance data (continued)
Maximum displacement
E2M28
E2M30