6.4 Replace the oil
Refer to
Figure: General view of the pump on page 11
for the items in brackets.
1.
Operate the pump for approximately ten minutes to warm the oil, then switch off
the pump. (This lowers the viscosity of the oil and allows the oil to be drained from
the pump more easily).
2.
Isolate the pump from the electrical supply and disconnect it from the vacuum
system.
3.
Remove the oil filler-plug.
4.
Place a suitable block under the pump-motor to tilt the pump and place a suitable
container under the oil drain-plug (gravity drain). Remove the oil drain-plug and
allow the oil to drain into the container.
5.
If the oil is dirty or contaminated:
▪
Refit the oil drain-plug and pour clean oil into the pump.
▪
Reconnect the pump to the electrical supply and operate the pump for about
5 to 10 minutes.
▪
Disconnect the pump from the electrical supply, remove the oil drain-plug and
allow the oil to drain out of the pump.
▪
Repeat this step until the oil reservoir is clean.
6.
Refit the oil drain-plug, remove the block and reconnect the pump to the vacuum
system.
7.
Fill a suitable container with clean oil and pour the oil into the filler hole until the
oil-level reaches the MAX level mark on the bezel of the oil sight-glass.
8.
Allow a few minutes for the oil to drain into the pump. If necessary, add more oil.
Refit the oil filler-plug.
6.5 Inspect and clean the inlet-filter
Refer to
Figure: Inlet-filter removal and replacement on page 30
.
1.
Unscrew the inlet adaptor and remove the inlet-filter and O-ring.
2.
Wash the filter in a suitable cleaning solution. Allow the filter to dry.
3.
Refit the O-ring, inlet-filter and inlet adaptor.
Page 29
A37132880_F - Maintenance
Содержание A37104902
Страница 43: ...Page 41 A37132880_F Service...