E2M18
1.05 litres
* To operate the pump when the ambient temperature is outside the range specified in
Operating and storage conditions on page 13
or to optimise pump performance when
processing condensible vapours, a different oil may be required.
3.5 Electrical data
Refer to
Table: Electrical data: three-phase motors on page 17
single-phase motors on page 17
. For motor current information please refer to the
motor rating plate. The motor start-up current is drawn for less than one second, so
time-lag fuses must be used to prevent unnecessary fuse failure when the pump starts.
Fuses should be to EN60269
. If using the pump at temperatures
lower than 13 °C, the start-up current will be drawn for longer; this may cause the motor
thermal overload device to open.
Table 5
Electrical data: three-phase motors
Pump item
number
Voltage (V)
Frequency
(Hz)
Full load
current
(A)
Recommended supply
protection (A)
A34310940
200 - 220
50
3.3
10
380 - 415
50
1.9
6
200 - 230
60
2.3
10
460
60
1.6
6
A36310940
200 - 220
50
3.3
10
380 - 415
50
1.9
6
200 - 230
60
3.4
10
460
60
1.6
6
Motor output rating (continuous)
50 Hz operation
0.65 kW
60 Hz operation
0.75 kW
Table 6
Electrical data: single-phase motors
Pump item number
Voltage
(V)
Frequency
(Hz)
Full load current (A)
A36315903, A34316903,
A34315903
220 - 240
230 - 240
50
60
4.6
5.0
A34315981, A36315981
115
230
60
60
11.0
5.5
A34315904, A36315904
100
100 - 105
200
200 - 210
50
60
50
60
12.0
11.0
6.0
5.5
Page 17