background image

 

Edu-Logger spirometer logger sensor 
900-226 

 
The  Edu-Logger  spirometer  sensor  can  be  used  for 
any  science  experiment  or  activity  which  can  utilize 
lung  capacity  such  as  in  the  fields  of  Psychology, 
Biology, Exercise Science, etc. 
 
The  sensor  comes  pre-calibrated  so  you  can  start 
experimentation right out of the box using this guide.  
 
Hundreds  of  possible  experimental  subjects  that  can 
be  done  with  the  900-226  sensors  are:  gas  flow  rates 
and  gas  flow  laws,  exercise  experiments,  studying 
lung function, lung physiology and many more. 
 
The  spirometer  sensor  uses  the  following  units  of 
measure: 

 

Liters  per  second  (L/s):      The  amount  of 
volume which passes through the sensor tube 
per second. 

 

Using the spirometer sensor: 

 
The  Edu-Logger  spirometer  sensor  comes  with 
laminated paper for use.   
 
Prior  to  experimentation,  roll  a  single  piece  of 
laminated paper into a tube which is then placed inside 
of  the  spirometer  sensor  (into  the  side  with  the  wider 
internal  opening).    The  paper  will  stick  out  from  the 
metal sensor tube about one inch.  By blowing into the 
paper instead of directly into the metal tube the sensor 
will remain more sanitary for later uses. 

Содержание 900-226

Страница 1: ...Edu Logger Spirometer Logger Sensor Guide 900 226 ...

Страница 2: ...eriments studying lung function lung physiology and many more The spirometer sensor uses the following units of measure Liters per second L s The amount of volume which passes through the sensor tube per second Using the spirometer sensor The Edu Logger spirometer sensor comes with laminated paper for use Prior to experimentation roll a single piece of laminated paper into a tube which is then pla...

Страница 3: ... software and browser based application can be downloaded for free at www edulab com as well as a full software user guide Note Make sure not to download and install both types of software they will conflict on the computer Procedure 1 Prior to initial use please review the Using the spirometer sensor section of the instructions starting on page 2 of this document 2 Install the Edu Logger software...

Страница 4: ...e 11 The spirometer sensor will give a live reading in the box to the left of the screen while plugged in 12 To run an experiment and collect data click Run experiment 13 To end data collection early click Stop experiment Tablet smart phone device Materials needed 900 226 Spirometer Sensor Laminated Paper included 900 268 WiFi module 900 215 Battery Your spirometer sensor needs to be connected to ...

Страница 5: ...68 units with the USB icon on the cover 6 For further 900 268 instructions or the 900 268 quick start guide please visit www edulab com 7 The 900 268 indicator lights will flash take no action until the LED to the far left turns blue this can take up to one minute 8 Take your tablet or smart phone go to the WiFi settings and select the Edu Logger network which matches the 900 268 Module ID found o...

Страница 6: ...er generation 900 268 with the USB icon on the cover this can be used as a 900 213 meaning you can tether the probes directly to the computer using the 900 268 To engage operation in this fashion press 3 times on the panel key Repeating this operation will return the unit to WiFi mode Operation with Edu Logger viewer Materials needed 900 226 Spirometer Sensor Laminated Paper included 900 272 Viewi...

Страница 7: ...odule USB to mini USB cable included with the 900 213 module Procedure 1 Prior to initial use please review the Using the spirometer sensor section of the instructions starting on page 2 2 Connect the spirometer sensor directly to the left side of a charged 900 215 module 3 When ready to collect data press the Start Stop button on the spirometer sensor a red light will turn on for the duration of ...

Страница 8: ...226 spirometer sensor Restoring sensor s factory default settings Procedure 1 Connect the 900 213 to a PC Mac tablet or smart device 2 Connect the spirometer sensor to a 900 213 module they directly plug together Please note there is no calibration required for this sensor 3 Open the Edu Logger software 4 Click the Tools icon 5 Click the Restore sensor s factory defaults on the menu 6 If prompted ...

Страница 9: ...ly digital data Rugged plastic ergonomic case Push button switch for Start Stop experiments in off line mode LED indicator of experiment status blinks while collecting data Pre calibrated sensing equipment Metal sensor tube attached by 2 durable rubber coated wires Two pressure sensors connected to the metal tube to accurately determine Note Edu Logger products are intended for educational use ...

Страница 10: ...for example The sensor is pre calibrated at the factory The built in software in the logger can be upgraded at any time using software Inside of the Edu Logger spirometer sensor s metal tube attachment there is a funnel which creates a difference of the air pressures before and after the funneling piece according to the airflow speed A pressure differential sensor is connected to both sides of the...

Страница 11: ...sunlight Warranty We promise to deliver our sensor free of defects in materials and workmanship for a period of 3 years from the date of purchase Our warranty does not cover damage of the product caused by improper use abuse or incorrect storage Sensors with a shelf life such as ion selective proves have a warranty of 1 year Should you need to act upon the warranty please contact your distributor ...

Страница 12: ...12 Thank you for using Edu Logger Flexible simple fast forward thinking W www edulab com E info edulab com V10012013 ...

Отзывы: