Materials needed: 
 

 

900-211 Force Sensor 

 

900-272 Viewing Module 

 

900-215 Battery 

 

Procedure: 

 
1.

 

Connect  the  force  sensor  to  the  left  side  of  the 
viewer. 

2.

 

Connect  the  900-215  module  to  the  right  side  of 
the viewer. 

3.

 

The 900-272 will auto detect  the sensor and  you 
will see it appear on the left side of the screen. 

4.

 

Once  the  sensor  appears  it  will  be  monitoring 
data in real time. 

5.

 

To  run  an  experiment  and  collect  data  click  the 
run button (little green person). 

 

Off-line experiments 

 
(Off-line experiments are for when you do not have a 
sensor  connected  directly  to  a  computer,  tablet, 
smartphone, or Edu-logger viewer). 
 

Materials needed: 

 

900-211 Force Sensor 

 

900-215 Battery Module 

 

Materials needed to configure your offline 
experiment: 
 

 

900-213  Module  or  900-268  module  or  900-272 
Module 

 

USB  to  mini  USB  cable  (included  with  the  900-
213 module). 

Procedure: 

1.

 

Connect  the  force  sensor  directly  to  the  left  side 
of a charged 900-215 module. 

Содержание 900-211

Страница 1: ...Edu logger Force Logger Sensor Guide 900 211...

Страница 2: ...set up to your specific requirements to give quick easy accurate and reliable data The sensor comes pre calibrated so you can start experimentation right out of the box using this guide The sensor can...

Страница 3: ...he left side of your screen 4 Remove all force from the sensor and click reset to zero your force sensor 5 You can also reset the sensor to zero by pressing and holding the sensor push button for 3 se...

Страница 4: ...f the screen the probe has been automatically identified and you can begin experimentation 6 If the force sensor is not automatically identified click the Search for sensors icon to find the sensor 7...

Страница 5: ...3 Although not required we recommend plugging the 900 215 to an outlet using a USB to mini USB charger such as a typical cell phone charger The 900 268 module will run for 15 75 minutes depending on t...

Страница 6: ...sensor is found you will see an icon on the left side of the screen for the force sensor The icon will display real time data 14 Click on the Module setup button located on the force sensor icon in th...

Страница 7: ...a in real time 5 To run an experiment and collect data click the run button little green person Off line experiments Off line experiments are for when you do not have a sensor connected directly to a...

Страница 8: ...vice full instructions in each device s quick start procedure section 5 Open Edu logger software 6 Click the Off line experiment button 7 Click the Load data from sensors button 8 Select which experim...

Страница 9: ...r dynamic experiments such as harmonic movement of spring with weight Sensor features Fully digital data Rugged plastic ergonomic case Push button switch for Start Stop experiments in off line mode LE...

Страница 10: ...mple The sensor is pre calibrated at the factory The built in software in the logger can be upgraded at any time using software The force sensor is based on a metal rod connected in both sides to the...

Страница 11: ...than 250 Newtons of force to the sensor Warranty We promise to deliver our sensor free of defects in materials and workmanship for a period of 3 years from the date of purchase Our warranty does not...

Страница 12: ...12 Thank you for using Edu logger Flexible simple fast forward thinking W www edulab com E info edulab com V10012013...

Отзывы: