Videos, literature and other probes can be found 
at 

www.edulab.com 

 

 
 

Technical background: 

 
The  philosophy  behind  Edu-logger’s  plug  and  play 
technology is based on each sensor’s ability to store its 
own  data  due  to  an  internal  flash  memory  chip  and 
micro-controller  in  each  plastic  Edu-logger  body.  
This  technology  allows  the  sensor  to  collect  and  then 
store the digital data in the correct scientific units (

o

C, 

o

F, Lux, %, ppm, for example). 

 
The sensor is pre-calibrated at the factory. The built-in 
software  in  the  logger  can  be  upgraded  at  any  time 
using software. 
 
The force sensor is based on a metal rod connected in 
both sides to the force sensor hooks in a special shape 
called 'S' shape. A strain gauge is attached to the metal 
rod  and  connected  to  a  very  sensitive  operational 
amplifier. 
 
Pulling  or  pushing  the  hooks  bends  very  little  the 
metal rod, changes the strain gauge resistances and the 
amplifier  output  voltage.  This  voltage  is  converted 
into force (N) by the sensor controller. 
 
 

Maintenance and storage: 

 

 

Never  submerge  the  Edu-logger  plastic  body  in 
any liquid 

Содержание 900-211

Страница 1: ...Edu logger Force Logger Sensor Guide 900 211...

Страница 2: ...set up to your specific requirements to give quick easy accurate and reliable data The sensor comes pre calibrated so you can start experimentation right out of the box using this guide The sensor can...

Страница 3: ...he left side of your screen 4 Remove all force from the sensor and click reset to zero your force sensor 5 You can also reset the sensor to zero by pressing and holding the sensor push button for 3 se...

Страница 4: ...f the screen the probe has been automatically identified and you can begin experimentation 6 If the force sensor is not automatically identified click the Search for sensors icon to find the sensor 7...

Страница 5: ...3 Although not required we recommend plugging the 900 215 to an outlet using a USB to mini USB charger such as a typical cell phone charger The 900 268 module will run for 15 75 minutes depending on t...

Страница 6: ...sensor is found you will see an icon on the left side of the screen for the force sensor The icon will display real time data 14 Click on the Module setup button located on the force sensor icon in th...

Страница 7: ...a in real time 5 To run an experiment and collect data click the run button little green person Off line experiments Off line experiments are for when you do not have a sensor connected directly to a...

Страница 8: ...vice full instructions in each device s quick start procedure section 5 Open Edu logger software 6 Click the Off line experiment button 7 Click the Load data from sensors button 8 Select which experim...

Страница 9: ...r dynamic experiments such as harmonic movement of spring with weight Sensor features Fully digital data Rugged plastic ergonomic case Push button switch for Start Stop experiments in off line mode LE...

Страница 10: ...mple The sensor is pre calibrated at the factory The built in software in the logger can be upgraded at any time using software The force sensor is based on a metal rod connected in both sides to the...

Страница 11: ...than 250 Newtons of force to the sensor Warranty We promise to deliver our sensor free of defects in materials and workmanship for a period of 3 years from the date of purchase Our warranty does not...

Страница 12: ...12 Thank you for using Edu logger Flexible simple fast forward thinking W www edulab com E info edulab com V10012013...

Отзывы: