Proper Operation of the Glass-Chek ELITE

Page 6

Place the meter at the bottom center of the window to be tested.  Press 

and release

 the POWER button to take a measurement.  Do not hold 

the POWER button down, as this will cause the meter to shut off.  The “TAKING READING” message will be displayed while your 
measurement is being completed.  The “TAKING READING” screen also indicates the remaining battery life, as well as confirms the operating 
MODE the meter is in. 

Turning The Meter Off

Hold the button down for several seconds to turn off the meter.  A message will display on the screen notifying you that the meter is about to 
power down.  Continue holding the button down until the screen goes blank.  If the meter is left unused for a period of time, the unit will 
automatically shut off.  To conserve battery life, it is recommended to turn the meter off manually when you are finished using it.

Guidelines For Most Accurate Results:

• Hold the meter steady and flat against the test surface during measurement 
• Do not touch the glass with your hand while taking the reading 
• Take readings at the 

 of the window for best 

thickness

   accuracy (see explanation below)
• Take multiple measurements to verify results
• Make sure the window being measured is clean
• Make sure the two lenses on the back of the GC3200 are clean.  See Image 
  to the right. --------> 

  Use only clean compressed air to clean the lenses.  Only use a lint
  free cloth if absolutely necessary to clean smudges, fingerprints, etc.

• Make sure nothing is touching the far side surface of the window during the
  measurement
• It is best to test windows in free air, not resting on a tabletop surface, or             
  stacked on other pieces of glass.

BOTTOM CENTER

Above:  Back of GC3200 meter with the two lenses
circled.  Use clean compressed air to clean the
lenses.

At Right:  Incorrect hand placement.

• DO NOT hold the POWER button while taking a measurement.  This will cause
the meter to turn off.  Rest your index finger next to the button as shown above.
• DO NOT touch the glass with your hand while taking readings.  The picture at
right shows the user’s thumb resting on the window while taking a measurement.
This could cause incorrect results for the low-E measurement. 

4 OPTIMAL TEST LOCATIONS

FOR MOST ACCURATE RESULTS

At Left:  Recommended placement of meter:

Hold the meter steady AND FLAT against the glass during measurement.  
The meter should be centered on one of the four edges of the window with the 
bottom edge of the meter placed parallel to the edge of the window (see image 
to the left).  BOTTOM CENTER IS THE PREFERRED LOCATION.  This will 
minimize the effect of a concave (or collapsed) window.  As you move away 
from the edge of a window, many windows will bow inward (concave).  
Because the sensor runs parallel to the bottom edge of the meter, it is 
important to place the bottom edge of the meter along the edge of the window 
as shown.  You can place the meter approximately 1 to 2 inches from the edge 
of the window.
DO NOT touch the glass with your hand or thumb while taking measurements.  
Note the hand placement used in the picture at left.  The user’s thumb is 
resting on the GC3200 without touching the glass being measured.  Also, be 
sure there are no other metallic objects touching the glass.          
DO NOT continue to hold down
the button while taking a 
measurement.  
Place your index finger next to 
the button as shown at left.  

Содержание Glass-Chek ELITE GC3200

Страница 1: ...n MENU Options Page 3 Navigating the MENU Unit of Measure Results Screen Speed Page 4 Operating MODES Page 5 Language Selection Back light Settings Stored Data Page 6 Proper Operation BEST Location fo...

Страница 2: ...G MENU screen appears Release the ARROW button once that screen appears You can enter the MENU system any time the meter is powered on by pressing and holding one of the ARROW buttons Please note that...

Страница 3: ...in fractions If decimal inches are chosen only the air space thickness and overall IG unit thickness will be shown in decimal inches The glass thickness will always be shown in fractions of an inch wh...

Страница 4: ...t results If you need to know the air space of the IG change the MODE to NORMAL GLASS NO LAMI and the GC3200 will measure the IG as a regular double pane window including the air space See the applica...

Страница 5: ...ff the back light until the measurement results are obtained This helps to extend the life of the battery Stored Data The GC3200 will automatically save the most recent 30 measurements The stored data...

Страница 6: ...st windows in free air not resting on a tabletop surface or stacked on other pieces of glass BOTTOM CENTER Above Back of GC3200 meter with the two lenses circled Use clean compressed air to clean the...

Страница 7: ...the meter did not detect a low E coating on G1 or G2 Since the GC3200 only detects coatings on the first 2 panes you may be required to test both sides of a triple pane window to verify the presence...

Страница 8: ...by showing the results as a combination of G1 L1 G2 When this occurs the meter was not able to cleanly identify the laminate inner layer surfaces Screen 4 below shows an example of how this will appe...

Страница 9: ...clear of any Low E coating In this example the clear glass lami 162 or 5 32 On screens 2 and 4 you will see that these two thickness values are denoted by the letter D D1 D2 Because the meter does no...

Страница 10: ...itional screen to the rotation of results screens The additional screen is called the ASSUMPTION SCREEN If the user knows that both pieces of glass in the laminated piece that are referenced in the AS...

Страница 11: ...to showing a D dimension that groups at least one component into the dimension The D dimension could include a variety of component thickness values in its result For instance the D dimension could i...

Страница 12: ...than one low e coating in the window the Glass Chek ELITE will only identify the first nearest Low E coating that it encounters Testing from the opposite side of the window would allow you to identify...

Страница 13: ...for low E measurement See the Specifications section on Page 15 of this manual for more details on the GC3200 s maximum thickness ranges Battery and replacement The GC3200 meter is powered by a 9 vol...

Страница 14: ...takes varying amounts of time depending on the application Be sure to hold the meter steady against the window until the results are displayed Measurements that will take longer include Laminated Gla...

Страница 15: ...ic Glass The GC3200 will display the thickness of single pane monolithic glass up to 2 75 inches or 70mm thick GLASS 1 GLASS 1 SINGLE LITE GLASS GLASS 2 GLASS 2 AIR SPACE 1 AIR SPACE 1 AIR SPACE 2 GLA...

Страница 16: ...assumes no liability for the consequential damages of any kind through the use or misuse of the GC3200 product by the purchaser or others No other obligations or liabilities are expressed or implied...

Отзывы: