RCX C-Link Series

Firmware

EDT, Inc.

2011 June 29

13

4.

Power-cycle the extender.

5.

If you are using a FOX framegrabber, ensure the fiberoptic cable is connected to channel 0 (the channel 
physically closest to the PCI bus). The extender need not be connected to a camera.

6.

Query the extender, to ensure it is there and recognized, by entering

 rcxload 

with no arguments. After 

you start

 rcxload, 

the LEDs on both devices will be lighted and not blinking.

Typical output appears thus:

pdv unit 0 (pci dv fox) chan. 0 RCX module:

sector 0 [10000]: <rgb11cm60_a01.ncd 2vp2fg256 2006/03/30 20:05:34>

sector 1 [38000]: <rgb11cm80_a01.ncd 2vp2fg256 2006/03/30 20:12:36>

sector 2 [60000]: <rgb11fg40_a01.ncd 2vp2fg256 2006/03/30 19:57:41>

sector 3 [88000]: <rgb11fg60_a01.ncd 2vp2fg256 2006/03/30 20:02:08>

sector 4 [b0000]: <rgb11fg80_a01.ncd 2vp2fg256 2006/03/30 20:09:30>

sector 5 [d8000]: <fud02b.ncd 2vp2fg256 2006/03/28 15:59:19>

If your output appears faulty, check the configuration code, cables, and connections. If you still have 
problems, email the output to [email protected].

7.

Assuming correct output from 

step 6

 above, you can perform either or both of the following operations.

— To verify (compare) the firmware in your EDT installation package against the firmware already 

loaded on your extender via flash memory, run...

rcxload -u 0 -v flash/rcx/

file.rcx 

...replacing

 file.rcx 

with the filename of the current firmware revision. The utility compares the 

firmware in the extender with the firmware in the specified firmware file. If they are the same, the 
utility reports

 verified 

and

 0 errors; 

if not, it reports

 not verified 

and lists the errors.

— To update the firmware, if you determine that an update is necessary, run...

rcxload -u 0 flash/rcx/

file.rcx 

...replacing

 file.rcx 

with the filename of the current firmware revision. 

The filename must be a valid

 .rcx 

file. EDT software packages ship with the current

 .rcx 

files in the 

flash/rcx 

subdirectory. The

 README 

file in the package has information about any

 .rcx 

file updates, 

including the specific filename of the current revision.

After a successful update, configure the extender for the desired operating mode (see 

Configuration 

and LED Configuration Codes on page 7

).

NOTE

If

 rcxload 

reports an error within a section flagged as “critical,” do not power-cycle the extender; 

instead, repeat the procedure. If you still get errors, leave the extender powered on and contact EDT.

You can turn off the power to the computer and camera, and leave the extender powered on indefinitely.

Содержание RCX C-Link series

Страница 1: ...User s Guide RCX C Link Series Remote Camera Link Extenders for use with Camera Link cameras Doc 008 02368 03d Rev 2011 June 29...

Страница 2: ...06 p 503 690 1234 800 435 4320 f 503 690 1243 www edt com EDTTM and Engineering Design TeamTM are trademarks of Engineering Design Team Inc All other trademarks service marks and copyrights are the pr...

Страница 3: ...f business profits or information and the like arising out of the use or inability to use the Products even if Seller has been advised of the possibility of such damages Because some jurisdictions do...

Страница 4: ...LED Configuration Codes 7 Base Mode 8 Medium or Full Mode 9 Resetting or Changing the Operating Mode 9 Backward Compatibility 10 Status and LED Status Codes 11 Firmware 12 Versions 12 Querying Verifyi...

Страница 5: ...version only NOTE All EDT extenders and framegrabbers mentioned in this guide are for Camera Link For details on our legacy AIA product RCX LVDS RS422 see its product page at www edt com Care and Cau...

Страница 6: ...Product Documentation EDT Resource Detail Web link Application programming interface HTML and PDF versions www edt com manuals html Installation packages Software firmware www edt com software html S...

Страница 7: ...device camera or framegrabber to the extender s MDR26 connector Cable end Attach the correct cable to the extender s cable connectors Figure 2 shows the extender connectors and other features includin...

Страница 8: ...vary from line to line and frame to frame With a standard framegrabber For a base mode system with a standard framegrabber you will need two extenders one at the camera end and one at the framegrabbe...

Страница 9: ...two MDR26 connectors The primary connector operates the same way as the base mode interface each pixel clock transfers 24 bits of video data from the camera s X channel The primary connector also can...

Страница 10: ...Figure 5 Full mode multiple extenders standard framegrabber To set up this system 1 Install your Camera Link framegrabber and software as instructed by its manufacturer 2 Verify extenders are configur...

Страница 11: ...links a configuration code indicating the operating mode for which the extender is configured one time and then blinks rapidly as the firmware loads After power on the LED continuously displays a stat...

Страница 12: ...lower power dissipation The selection of 16 bit mode is made only at the framegrabber end through configuration code 2 2 or through the directive mode16 1 in a FOX configuration file this information...

Страница 13: ...prevent future confusion To reset or change the operating mode configuration code 1 Turn off the power to the extender and disconnect the extender from everything except a power supply NOTE EDT recom...

Страница 14: ...t digit then repeat for the second digit For example for a configuration code of 2 1 press the button for two blinks and release then press the button for one blink and release As soon as you enter th...

Страница 15: ...uration Codes on page 7 The cable connection is compromised either by incorrect or damaged cabling or by moisture or debris in the extender s cable connectors see Care and Cautions on page 1 Fast blin...

Страница 16: ...indicating an unsupported configuration code then you have firmware of revision 11 or later Querying Verifying and Updating For base or medium mode follow the steps below to query verify and update th...

Страница 17: ...ons To verify compare the firmware in your EDT installation package against the firmware already loaded on your extender via flash memory run rcxload u 0 v flash rcx file rcx replacing file rcx with t...

Страница 18: ...y over a single fiber DualTX and DualRX transceivers In full mode these are used on the secondary Camera Link con nector because it must carry twice as much data as the primary connector Coaxial Cable...

Страница 19: ...ull mode secondary connector 1 1 inner shield inner shield inner shield 14 14 inner shield inner shield inner shield 2 25 X0 Y0 Y0 15 12 X0 Y0 Y0 3 24 X1 Y1 Y1 16 11 X1 Y1 Y1 4 23 X2 Y2 Y2 17 10 X2 Y2...

Страница 20: ...at is local to either end If you wish to explore these options contact EDT Unlike the DB9 in the female assembly this DB9 has no looped back signals or integrated level conversion Table 7 Pinout Lemo...

Страница 21: ...s 1 4 and 6 are wired together and unconnected 7 and 8 also are wired together and 9 also is unconnected these signals are not otherwise used Table 8 Pinout Male DB9 Cable Lemo Pin Color DB9 Pin Stand...

Страница 22: ...he tables under Configuration and LED Configuration Codes on page 7 select a configuration code with a frequency range that is included in the frequency generated by the cable assembly Table 10 shows...

Страница 23: ...chcraft connectors while the two extenders at the framegrabber end can receive power from the EDT resync cable through a female DB9 connector The resync cable connects to the extenders through two int...

Страница 24: ...imension of 0 31 inch is for the standard power connector the optional Lemo connector on the fiber version is approximately 0 35 inch NOTE Connector dimensions are approximate for precise dimensions s...

Страница 25: ...ers and instructions Figure 11 EDT extenders with EDT half meter adapter cables Also for devices with SDR mini Camera Link connectors EDT offers a 3M MDR26 female to SDR26 male cable in two lengths 1...

Страница 26: ...ly added clarifying details and a fig ure showing the standard Switchcraft vs the optional Lemo power connector 20110523 03b CH PH 18 Under Power Supply expanded the opening verbiage to Each extender...

Отзывы: