  Installation Guidelines 

 

Step 1 

Check All Bolts

  - Make sure that all bolts on the pump are tight. Tools: 2ea. 9/16”, 1/2” and 

 

 

7/16” Box Wrenches & 1 Allen Wrench.  

7/16”  

Upper Standard  

& Head Ring 

1/2”  

Cylinder Mounting Nuts (Not Shown) 

9/16”  

Cylinder Rod  

Locking Nut 

 

Step 2 

Place Pump 

- The pump must be installed so that the flapper valves will open and close. The drawings 

 

 

 below show how the pump can and can not be installed in relationship to its’ horizontal and vertical axis.  

Page 3 Installation 

 

         

P-220A-03 

Содержание 220A Series

Страница 1: ...owered Diaphragm Base Mount Bronze 1 1 2 Inlet and 1 1 2 Discharge Make sure the pump received is the pump ordered Compare the pump with the packing list Make sure the parts list attached to this manu...

Страница 2: ...0 Cycles Per Min 5 feet 1 5 m eters 1 foot 3 meters 10 feet 3 meters 17 feet 4 2 m eters 5 feet 1 5 meters 12 9 gpm 49 lpm 12 5 gpm 47 5 lpm 11 8 gpm 44 8 lpm 5 gpm 19 lpm 12 1 gpm 46 lpm 12 1 gpm 46...

Страница 3: ...Wrench 7 16 Upper Standard Head Ring 1 2 Cylinder Mounting Nuts Not Shown 9 16 Cylinder Rod Locking Nut Step 2 Place Pump The pump must be installed so that the flapper valves will open and close The...

Страница 4: ...you need once the plumbing is installed and liquid is being pumped 1 Open the air line 2 Set air line pressure to 90 psi 3 Using a very small flat head screwdriver start closing clockwise the right h...

Страница 5: ...nder the force of gravity liquid will pass right through a diaphragm pump Also consider a diaphragm pump can not control a siphon condition They are used many times to start one lDISCHARGE FITTINGS PI...

Страница 6: ...dry suction start performance of the pump and make clearing the valves easy Order Edson Clear Check V alves 69CL 150 1 5 lPUMPING AT THE PROPER SPEED When pumping liquid with solids the speed may be t...

Страница 7: ...stallation is different so use the charts as a guideline 6 Example 1 The fill test at 30 GPM The diaphragm is going up and down at 56 cycles per minute The pump is approximately 6 ft above the liquid...

Страница 8: ...6 to 7 psi and when the pump is stopped the pressure may hold or slowly returns to 0 4 If you do not get any pressure reading or if the gauge does not get to 4 psi and drops off to 0 as soon as the p...

Страница 9: ...he cause is not obvious isolate the source Check air line for pressue and flow If ok discon nect the inlet and discharge plumbing from the pump and restart the pump If pump cycles without the plumbing...

Страница 10: ...Edson Customer Service for details 4 Problem Pump base and or lines keep filling with solids Possible Causes a Line velocity is too slow to keep the solids in suspen sion b The percent of solids is t...

Страница 11: ...S w Nut 5 16 24 Nut 160 B 376A Discharge Chamber 160 A 1207 Valve Assembly 160 A 1207 Valve Assembly 160 B 374B Head Ring 160 B 375A Suction Chamber 160 B 378A Pump Base 10 32 X 3 4 PHMS Parts 220ACA...