Edson 220A Series Скачать руководство пользователя страница 11

146 DUCHAINE BLVD., NEW BEDFORD, MA.  02745-1292    TEL.  508-995-9711    FAX  508-995-5021     E-MAIL  [email protected]

Pump Spares Kits:

161 A-

2994

 Air Cylinder

,QFOXGHV$6SHHG&RQWURO0XIIOHUV

160- B-387

B

Adapter Frame

1/4-20 X 3/4” HHCS

160-A-1253 Sealing Washer

161-A-1008 Upper Standard

161-A-1006 Lower Standard

113N-18 Nitrile Diaphragm

1/4-20 X 2” HHCS w/Nut & Washer

10-32 X 3/4” PHMS w/Nut

5/16-24 Nut

160-B-376A

Discharge Chamber

160-A-1207 Valve Assembly

160-A-1207 Valve Assembly

160-B-374B Head Ring

160-B-375A

Suction Chamber

160-B-378A

Pump Base

10-32 X 3/4” PHMS

   Parts  220ACA-150

Viton

Order No. 114V 18-220

1 Diaphragm

113V - 18

2 Valve Assemblies 160  A-1207V

2 Sealing Washers  160 A-1253

Nitrile

Order No. 114N 18-220

1 Diaphragm

113N -18

2 Valve Assemblies 160  A-1207

2 Sealing Washers 160  A-1253

Viton

Order No. 114V 18-220

1 Diaphragm

113V - 18

2 Valve Assemblies 160  A-1207V

2 Sealing Washers  160 A-1253

   Parts: Spares Kits

Page 11 Parts

P

-220A-03

 

Содержание 220A Series

Страница 1: ...owered Diaphragm Base Mount Bronze 1 1 2 Inlet and 1 1 2 Discharge Make sure the pump received is the pump ordered Compare the pump with the packing list Make sure the parts list attached to this manu...

Страница 2: ...0 Cycles Per Min 5 feet 1 5 m eters 1 foot 3 meters 10 feet 3 meters 17 feet 4 2 m eters 5 feet 1 5 meters 12 9 gpm 49 lpm 12 5 gpm 47 5 lpm 11 8 gpm 44 8 lpm 5 gpm 19 lpm 12 1 gpm 46 lpm 12 1 gpm 46...

Страница 3: ...Wrench 7 16 Upper Standard Head Ring 1 2 Cylinder Mounting Nuts Not Shown 9 16 Cylinder Rod Locking Nut Step 2 Place Pump The pump must be installed so that the flapper valves will open and close The...

Страница 4: ...you need once the plumbing is installed and liquid is being pumped 1 Open the air line 2 Set air line pressure to 90 psi 3 Using a very small flat head screwdriver start closing clockwise the right h...

Страница 5: ...nder the force of gravity liquid will pass right through a diaphragm pump Also consider a diaphragm pump can not control a siphon condition They are used many times to start one lDISCHARGE FITTINGS PI...

Страница 6: ...dry suction start performance of the pump and make clearing the valves easy Order Edson Clear Check V alves 69CL 150 1 5 lPUMPING AT THE PROPER SPEED When pumping liquid with solids the speed may be t...

Страница 7: ...stallation is different so use the charts as a guideline 6 Example 1 The fill test at 30 GPM The diaphragm is going up and down at 56 cycles per minute The pump is approximately 6 ft above the liquid...

Страница 8: ...6 to 7 psi and when the pump is stopped the pressure may hold or slowly returns to 0 4 If you do not get any pressure reading or if the gauge does not get to 4 psi and drops off to 0 as soon as the p...

Страница 9: ...he cause is not obvious isolate the source Check air line for pressue and flow If ok discon nect the inlet and discharge plumbing from the pump and restart the pump If pump cycles without the plumbing...

Страница 10: ...Edson Customer Service for details 4 Problem Pump base and or lines keep filling with solids Possible Causes a Line velocity is too slow to keep the solids in suspen sion b The percent of solids is t...

Страница 11: ...S w Nut 5 16 24 Nut 160 B 376A Discharge Chamber 160 A 1207 Valve Assembly 160 A 1207 Valve Assembly 160 B 374B Head Ring 160 B 375A Suction Chamber 160 B 378A Pump Base 10 32 X 3 4 PHMS Parts 220ACA...

Отзывы: