12
Installation—Speed Control Mode
The speed controller has 4 operating modes. These can be cycled
through by pressing the button on the speed controller.
The order of modes are: LO. MED. HI, AUTO. When engaging AUTO
mode the fan will speed up to full speed and then slow down to a
stop to provide feedback that AUTO has been selected. Once this
startup procedure is complete the fan will analyse the environment
and run at the appropriate speed.
MODES:
LO (Default)
- Continuous operation, low speed, low flow rate,
very quiet, very low power consumption.
MED -
Continuous operation, moderate speed, moderate flow
rate.
HI -
Continuous operation, high speed, high flow rate.
AUTO -
Variable speed. The AiroMatic will automatically
increase or decrease the speed of the fan depending on
roof cavity temperature (30°C - 45°C) and roof cavity
relative humidity (65%rH—80%rH).
In AUTO mode the AiroMatic will run based off the environmental
conditions. When the conditions are deemed suitable for no ventilation
the unit will enter power saving mode and the motor will not run.