![Edirol Studio Canvas SD-90 Скачать руководство пользователя страница 46](http://html.mh-extra.com/html/edirol/studio-canvas-sd-90/studio-canvas-sd-90_owners-manual_2362006046.webp)
46
Using the effects of the internal sound generator
MFX A-C Reverb Send Level (Multi-effect A–C Reverb Send Level)
0–127
Specifies the level at which the signal processed by the multi-effect will be sent to the Reverb effect.
MFX A-C Control 1-4 Source (MFX A–C Control 1–4 Source)
Specifies the control source that will modify the multi-effect parameter, and the sensitivity of the control.
MFX A-C Control 1-4 Sens (MFX A–C Control 1–4 Sensitivity)
-63–+63
Set this to a positive (+) value if you want to apply changes to the present value in the positive direction
(higher value, toward the right, faster, etc.). Set this to a negative value (-) if you want to apply changes to
the present value in a negative direction (lower value, toward the left, slower, etc.). The greater the value,
the greater the change produced.
MFX A-C Parameter 1-32 (MFX A–C Parameter)
Specifies the parameter of the multi-effect that you want to use. The parameters that can be edited will
depend on the type of multi-effect you select in MFX Type (Multi-effect Type). For details on each effect
parameter, refer to
MFX_E.pdf
in the included CD-ROM.
Using MFX in Native mode
If you switch the sound generator to
Native mode
, you will be able to control the sound and
MFX
independently. In order to apply
MFX
to the sound of a specific part, you must do the following two
things.
• Select the location (source) of the parameters used by MFX.
• Send the output of the part to MFX.
Select the location of the parameters used by MFX
MFX A SOURCE (MFX A source)
COMMON,
PART 1–32
MFX B SOURCE (MFX B source)
COMMON,
PART 1–32
MFX C SOURCE (MFX C source)
COMMON,
PART 1–32
MFX parameters (e.g., algorithm, reverb type, distortion type) exist both within the sounds (COMMON)
and outside them. For each of the three
MFX
units, you can specify which parameters the unit will use.
COMMON:
One of the three sets of parameters stored outside the sounds will be used. A part whose
Part Output MFX Select
setting is set to
MFX
will use the effect settings you specify, and
will not be affected by the effect settings of the sound that is called up for that part.
PART 1–32:
The parameters stored within the sound called up for that part will be used. Parts whose
Part Output MFX Select
setting is set to
MFX
will be processed by the MFX effect settings
of the part referenced by
MFX
. When another sound is called up for the part that is
referenced, MFX A will operate according to the MFX settings of the newly requested
sound, and the previously mentioned parts will also be processed by these effect settings.
Value
Explanation
OFF
A controller will not be used.
CC01–95
Controller number 1–95 (except for 32)
PITCH BEND
Pitch bend
AFTERTOUCH
Aftertouch
SYS-CTRL 1–4
System control 1–4
sd90_manual_e.book 46 ページ 2004年10月4日 月曜日 午後3時28分