(3) Speed (100M / 10M) Configuration
This switch provides the force speed function. You can refer
the following procedure to setup the speed of switching ports.
Step 1.
Press the
Function
button until the
Speed
LED is on.
Step 2.
Press the
Port
button to scroll between the port 1 to 16.
Step 3.
Press the
Set
button to assign the speed of selected port to 100Mbps or
10Mbps. After you press
Set
button ,the selected port’s 10M (Status) LED
and 100M (Group) LED will switch between on and off. If the selected
port’s 10M LED is on and 100M LED is off, the select port is forced to
10M. If the selected port’s 10M LED is off and 100M LED is on, the select
port is forced to 100M. If the selected port’s 10M LED is on and 100M
LED is on, the select port is set to auto sensing.
Step 4.
Press the
Function
button until the
SAVE
LED is on.
Step 5.
Press the
Set
button to save the setting.
Step 6.
Press the
Function
button to return to normal mode.
(4) Full/Half-Duplex
Configuration
This switch provides the force Full/Half Duplex Mulde function.
You can refer the following procedure to setup the full/half duplex
mode of switching ports.
Step 1.
Press the
Function
button until the
Full/Half Duplex
LED is on.
Step 2.
Press the
Port
button to scroll between the port 1 to 16.
Step 3.
Press the
Set
button to assign the selected port to
Full
or
Half
Duplex
.
After you press
Set
button ,the selected port’s Full (Group) LED and Half
(Status) LED will switch between on and off. If the selected port Full LED
is on and Half LED is off, the select port is force to Full Duplex. If the
selected port Full LED is off and Half LED is on, the select port is force to