- 36
-
ENGLISH
ELECTRICAL CHARACTERISTICS
Power supply
230 Vac +/- 10% 50 Hz
Average power consumption
120 - 150 W
Power consumption during ignition
400 W
Remote control frequency
2,4 GHz
Protection on electronic circuit board
Fusibile 2AT, 250 Vac 5x20
N.B.
1) keep in mind that external devices can cause interference to the operation of the circuit board.
2) warning: activity on live components, maintenance and/or checks must be carried out by qualified personnel.
(before carrying out any maintenance, disconnect the appliance from the mains electricity)
3) In case of problems with the electrical grid, consult an electrician to evaluate the installation of a UPS of at least 800
Vac. Power variations greater than 10% can cause problems for the product.
The above data are indicative and are those resulting during certification on the part of the notified body.
EDILKAMIN s.p.a. reserves the right to change the products at its discretion without notice.
SAFETY DEVICES
• THERMO COUPLING:
located on the smoke exhaust, detects the temperature. On the basis of the parameters set, check the ignition, working and turn-off
phases.
• VACUUM GAUGE:
Positioned on the smoke extractor, which detects the vacuum value (compared to the installation environment) in the combustion
chamber
• SAFETY THERMOSTAT:
Intervenes when the temperature within the insert is too high. Blocks pellet loading causing the insert to turn off.
• ROOM TEMP. DETECTION PROBE:
located on the remote control. Alternatively it can be connected up to the electronic board inside the insert.
GENERAL INFORMATION
* The heatable room dimensions are calculated on the basis of home insulation in compliance with Italian law 10/91, and subse-
quent changes together with an expected heat output of 33 Kcal/m³ per hour.
THERMO TECHNICAL CHARACTERISTICS
according to EN 14785)
PELLKAMIN 8
PELLKAMIN 10
Nominal power
Reduced power
Nominal power
Reduced power
Thermal power output
8,1
3,1
10,4
3,1
kW
Yield / Efficiency
91,1
90,3
90
90,3
%
Emissions CO 13% O
2
0,011
0,055
0,013
0,055
%
Fume temperature
145
100
172
100
°C
Fuel consumption
1,9
0,7
2,4
0,7
kg/h
Hopper capacity
11
11
kg
Draught
12 - 5
10 - 3
12 - 5
10 - 3
Pa
Autonomy
6
16
5
16
hours
Heatable volume *
210
270
m
3
Smoke outlet pipe diameter (male)
80
80
mm
Air intake pipe diameter (male)
40
40
mm
Weight including packaging
153
147
kg
TECHNICAL DATA FOR SIZING THE FLUE which must, in any case, comply with the guidelines of
this sheet and the installation rules for each product
PELLKAMIN 8
PELLKAMIN 10
Nominal power
Reduced power
Nominal power
Reduced power
Temperature of fumes on exit from the discharge pipe
174
120
207
120
°C
Minimum draught
0,01
Pa
Fume flow capacity
5,5
3,7
6,4
3,7
g/s
Содержание PELLKAMIN 10
Страница 30: ......
Страница 31: ......
Страница 32: ... 254 cod 941198 GB 12 17 H w w w e d i l k a m i n c o m ...