INSTALLING THE WATER CIRCUIT
Flamma is designed to install to a water circuit with
open expansion vessel.
Flamma Cs can be installed to circuits with open
expansion vessels (check local regulations), so long as
you hook up the fittings to the coil’s thermal discharge
valve.
INSTALLATION
Never light the fire in the hearth (even to test
it) when the circuit is dry (no water); doing so
can irreparably damage the appliance.
pLUMBING
Plumbing depends on the type of system.
However, there are some “general rules”:
• the presence of an accumulator (tank) is
recommended but not mandatory. Its advantage is
that it releases the boiler from “sudden” requests
from the system and can be integrated with other
heat sources. It reduces fuel consumption and
increases the efficiency of the system.
• The return temperature of the water to the boiler must
be higher than 50-55° C to prevent condensation.
• An accumulator (tank) is needed to heat
lowtemperature radiant panels, to be installed as
recommended by the manufacturer of the panels
themselves.
• The material used in the circuit must be suitable to
withstand overheating.
• direct plumbing to radiators prevents proper
operation, owing to the small diameter of their
pipes.
For simple installation, edilkamin offers pre-assembled
kits for installation outside the product.
the product you require depends on the type of circuit
you are installing.
In any case, the product’s delivery and return fittings
are at the back.
EXTERNAL WATER CIRCUIT KITS (OpTIONAL)
FOR OpEN/CLOSED EXpANSION VESSEL