INSTALLATION

REMARKS ON INSTALLATION

Note that:
•  the appliance may only be installed by a qualified 

technician authorised to issue the declaration of 
conformity.

•  the appliance must be installed and operated 

in compliance with local and national law and 
european regulations. the applicable Italian 
regulation is UNI 10683.

•  If installed in a condominium, the appliance must 

be approved by the administrator.

We give some general instructions below, however 
these do not obviate the need to comply with local 
regulations and do not affect the installer’s liability for 
the installation.

Checking the suitability of the installation 
space 

•  the room must have a volume of at least 20 m

3

•  the floor must be able to bear the weight of the 

product and its accessories.

•  level the appliance
•  the appliance may not be installed in a bedroom, 

bathroom or in the same room as other equipment 
which draws air for combustion from the room 
itself, or in any area with an explosive atmosphere. 
Any extraction fans operating in the same room or 
area as the product, may affect its draw.

•  In Italy, check the compatibility pursuant to UNI 

10683 and UNI 7129 in the presence of gas fired 
products.

protection from heat and safety clearances 

the surfaces of the building adjacent to the product 
must be protected against overheating.
the insulation to be used will depend on the type of 
surface in question.

the product must be installed in observance of the 
following safety instructions:
- minimum clearance at the sides and back of 20 cm 
from flammable materials. 
- no flammable materials may be kept closer to the 
front of the appliance than 80 cm. 
If installed on a flammable or combustible floor, or 
which is not capable of bearing its load, use steel or 
glass plates under the stove to distribute the load.
Contact the retailer for such optional equipment.

EXTERNAL AIR INTAKE

to re-integrate burnt oxygen during stove functioning, 
you need to have an installation premises suitable for 
the external air intake.
In general, we suggest two ways for ensuring a proper 
flow of combustion air.

Indirect air intake

Install an intake at floor level with effective area (net of 
the mesh or other protective equipment) of at least 200 
cm

2

 (16 cm dia.).

to prevent draughts, we recommend installing the 
intake behind the stove or behind a radiator.
Installing it in front of the appliance will create 
unpleasant draughts.

Direct air intake

Install an air intake of effective area (net of the mesh or 
other protective equipment) at least equal to that of the 
air intake at the back of the product.
Connect the air intake to the appliance’s air intake with 
a tube (which may also be flexible).
We recommend not exceeding a 3 m length depending 
on the draw of the flue.

the air maty be drawn from an adjacent room only if:
•  the flow is taken from permanent and unobstructed 

openings communicating with the outdoors;

•  the adjacent room is never in underpressure 

relative to the outdoors;

•  the adjacent room is not a garage. subject to fire 

hazard, a bathroom or bedroom

•  the adjacent room is not a shared room in the 

condominium.

Содержание fLAMMA

Страница 1: ...UK Installation use and maintenance WOOD Boiler stove fLAMMA flamma cs...

Страница 2: ...Vincenzo Monti 47 20123 Milan Italy VAT IT00192220192 Declares under its own responsability as follows The below listed wood burning stoves comply with EU Regulation 305 2011 and the harmonized Europe...

Страница 3: ...m www edilkamin com After unpacking the product check the condition and completeness of the contents In the event of error immediately contact the retailer where the purchase was made providing him wi...

Страница 4: ...possibly smoke in the environment cleaning of the smoke channel with various sub stances DO NOT CLEAN WITH FLAMMABLE PRODUCTS There is a risk of fires back draft cleaning of the hot glass with unsuit...

Страница 5: ...it thermal discharge valve Flamma CS internal dimensions of hearth cm 33 L x 34 P x 38 H F 15 134 56 63 ACS R AFS M F fumes discharge A air intake Vs safety valve M M 3 4 delivery R M 3 4 return AFS D...

Страница 6: ...CO 13 O2 0 208 0 092 Fume temperature 187 137 C Minimum draught 12 12 Pa Fuel consumption 6 1 3 5 kg h Heatable volume 615 360 m3 Water Content 40 40 l Max pressure 1 5 1 5 bar Top fumes outlet diame...

Страница 7: ...movement in a vertical position with suitable devices paying attention to the safety standards in force Do not overturn the packaging and be cautious when assembling parts The packaging includes a us...

Страница 8: ...e protected from mechanical knocks that could damage them V A B C D INSTALLING THE CERAMIC PANELS The ceramics kit includes n 8 side ceramic panels with pre installed rubber parts A n 1 top front inse...

Страница 9: ...illes G Fasten them with the 4 dome bolts already screwed into the frame Fit the rubber dampers included with the appliance Position the top D Use the bolts V on the top front panel above the air gril...

Страница 10: ...rom your reseller if you want to be able to heat the room up more quickly The kit is composed of a fan with electrical equipment To install the kit remove the back panel 1 by slackening off its two bo...

Страница 11: ...e following safety instructions minimum clearance at the sides and back of 20 cm from flammable materials no flammable materials may be kept closer to the front of the appliance than 80 cm If installe...

Страница 12: ...h solid fuel or that of the highest floor must be at least 50 cm taller must go beyond the reflux zone must enable chimney maintenance INSTALLATION CHIMNEY SYSTEM Smoke channel chimney flue and chim n...

Страница 13: ...system and can be integrated with other heat sources It reduces fuel consumption and increases the efficiency of the system The return temperature of the water to the boiler must be higher than 50 55...

Страница 14: ...s supply pressure since this may be in excess of the appliance s pressure rating and result in damage to the appliance itself The safety line to the expansion vessel must be able to vent freely withou...

Страница 15: ...s supplied with the kit itself rw2 KIT For simple installation Edilkamin offers pre assembled kits for installation inside the product The product you require depends on the type of circuit you are in...

Страница 16: ...omatic oils e g eucalyptus Cast iron parts can deteriorate Use the recommended quantities of wood Overloading causes overheating resulting in damage possible deformation of the inner parts possible ir...

Страница 17: ...aterials such as petrol alcohol and similar to switch on 4 At this point close the door and monitor it for a few minutes If the fire should extinguish slowly open the door re position another fireligh...

Страница 18: ...e last combustion No tray for removing or emptying present Cleaning the glass You can use specific products to clean the glass see our Glasskamin pricelist Do not spray the product on painted parts or...

Страница 19: ...e end of its service life dispose of the product as required by regulations Cleaning the interior of the stove Depending on the amount of use and at least once every season remove the refractory and m...

Страница 20: ...conditions remove the ash and brazier using tools and only touch metal containers with fireproof gloves in the event of a fire ask the authorities for help 5 In case of odours check if If first switc...

Страница 21: ......

Страница 22: ......

Страница 23: ......

Страница 24: ...cod 941299 GB 10 16 B w w w e d i l k a m i n c o m 941299 GB...

Отзывы: