LMD222 and LMD224 Series 

Operations Manual 

Eberle Design Inc. 

Page 9 

Section 4  

Specifications 

4.1 MECHANICAL  

Height ......................................................................................................... 4.50 inches 
LMD222 Width  ........................................................................................... 1.14 inches 
LMD224 Width  ........................................................................................... 2.34 inches 
Depth (excluding handle) ...........................................................................6.875 inches 

4.2 ENVIRONMENTAL  

Storage Temperature Range ...................................................................  -45 to +85 

o

Operating Temperature Range ................................................................  -34 to +74 

o

Humidity Range (non-condensing) ..................................................... 0 to 95% Relative 

4.3 ELECTRICAL 

DC Supply Voltage Minimum ...........................................................................10.8 Vdc  
DC Supply Voltage Maximum ..........................................................................28.8 Vdc  
DC Supply Current ........................................................................... 100 mA Maximum 
Optically Isolated Solid State Outputs 

True (low, 50 mA) .......................................................................less than 1.5 Vdc 
Maximum Leakage Current (DC Supply = 24Vdc) .......................................... 1 uA 
Maximum Current (low) ............................................................................ 100 mA 

Relay Outputs 

AC Contact Rating .......................................................................... 5A @ 120 Vac 
DC Contact Rating ............................................................................ 5A @ 30 Vdc 

4.4 TUNING 

4.4.1 LOOP INDUCTANCE (TUNING) RANGE 

The detector will automatically tune to a loop and lead-in combination within the tuning 
range of 20 to 2500 microHenry with a Q factor greater than 5. 

4.4.2 ENVIRONMENTAL TRACKING 

The detector automatically and continuously compensates for component drift and 
environmental effects throughout the tuning range and across the entire temperature range. 

4.4.3 GROUNDED LOOP OPERATION 

Each detector channel will operate when connected to poor quality loops including those 
that have a short to ground at a single point. 

4.4.4 LEAD-IN LENGTH 

The unit will operate with lead-in (feeder) lengths over  1,000 feet with appropriate loops 
and proper lead-in cable. 

4.5 LOOP INPUT (LIGHTNING PROTECTION) 

The loop input incorporates lightning and transient protection devices and the loop 
oscillator circuitry is transformer-isolated for each channel. The lightning protection will 
withstand the discharge of a 10uF capacitor charged to 2,000V across the loop inputs or 
between a loop input and Earth Ground for each channel. The transformer isolation allows 
operation with a loop which is grounded at a single point. 

Содержание LMD222

Страница 1: ...IS MANUAL CONTAINS TECHNICAL INFORMATION FOR THE LMD222 LMD224 and LMD222 R SERIES INDUCTIVE LOOP MONITOR REVISION AUGUST 2015 pn 888 0222 003 LMD222 and LMD224 Inductive Loop Monitor Operations Manua...

Страница 2: ...01 2008 REGISTERED COMPANY INFORMATION CONTAINED HEREIN IS PROPRIETARY TECHNICAL INFORMATION OF EBERLE DESIGN INC PUBLICATION REPRODUCTION OR USE IN WHOLE OR PART IS NOT PERMITTED EXCEPT UNDER TERMS A...

Страница 3: ...ff Mode 5 2 3 Set the Frequency 5 2 3 1 Displaying the Loop Frequency 5 2 4 Miscellaneous 5 2 4 1 Channel Off 5 2 4 2 Retune or Reset a Channel 6 2 4 3 Factory Default Settings 6 2 5 Loop Fault Monito...

Страница 4: ...ept to the inductive loop detector field that revolutionizes the process of installing and programming a loop detector The new user interface of the LMD Series provides the feedback necessary to the s...

Страница 5: ...rle Design Inc Page 2 The unit will detect inductance changes as small as 0 010 L L Each channel is sequentially energized and sampled so as to negate the possibility of crosstalk between loops connec...

Страница 6: ...ading 5 This is done by pressing the front panel SENS down button twice If a mid size vehicle located over the roadway loop causes the value 2 to be displayed on the DEFLECTOMETER the sensitivity shou...

Страница 7: ...hree seconds Pressing the SENS or SENS button during this interval will modify the Sensitivity Level as described in section 2 1 1 with the DEFLECTOMETER display remaining in the Call Strength mode Pr...

Страница 8: ...several seconds The Frequency level needs to be changed only if interference occurs between adjacent loops connected to different sensor units Interference or crosstalk may manifest itself as chatteri...

Страница 9: ...cuit loops shorted loops or sudden changes in inductance exceeding 25 of the nominal inductance 2 5 1 CURRENT FAULT If a fault is detected both the DET Red and FLT Yellow LEDs continuously emit a sequ...

Страница 10: ...in the vicinity of the saw slot should also be removed so that it is not accidentally pushed back in As a general rule loops with circumference lengths less than 12 feet require 5 turns of wire 12 to...

Страница 11: ...to the bottom of the slot and completely encase the loop wire The wire should not be able to move when the sealant has set Ensure that there is enough sealant to completely fill the slot if possible...

Страница 12: ...he tuning range of 20 to 2500 microHenry with a Q factor greater than 5 4 4 2 ENVIRONMENTAL TRACKING The detector automatically and continuously compensates for component drift and environmental effec...

Страница 13: ...nnel 1 Redundant Loop Input E Channel 1 Loop Input 5 Channel 1 Redundant Loop Input F Channel 1 Output 6 Reserved H Channel 1 Output 7 Reserved J Channel 2 Loop Input 8 Channel 2 Redundant Loop Input...

Страница 14: ...eserved N Reserved 12 Reserved P Channel 3 Loop Input 13 Channel 3 Redundant Loop Input R Channel 3 Loop Input 14 Channel 3 Redundant Loop Input S Channel 3 Output 15 Reserved T Channel 3 Output 16 Re...

Отзывы: