Normal Sounds 

  High Pitched Chatter- High efficiency compressors may have 

a high pitched chatter during the cooling cycle. 

  Sound of Rushing Air- At the front of the unit, you may hear 

the sound of rushing air being moved by the fan. 

  Gurgle/Hiss- Gurgling or Hissing noise may be heard due to 

refrigerant passing through evaporator during normal 
operation. 

  Vibration- Unit may vibrate and make noise because of poor 

wall or window construction or incorrect installation. 

  Pinging or Switching- Droplets of water hitting condenser 

during normal operation may cause these sounds. 

 

Energy Saving Guide 

 
Read and follow the guide below to get the best performance and 
efficiency from your window air conditioner: 

  Do not cover the air outlet (exhaust) while in use. 

  Use the timer to operate the unit before it is needed. For 

example, set the timer to turn on the unit in cooling mode for 3 
or more hours to cool the room before you arrive. You may want 
to operate the unit all day if you live in a warmer climate. 

  Minimize the heat sources (direct sunlight, computers, servers, 

people, etc.) in the room. 

  Close all windows and doors. 

  Use the unit in a contained room. For example, a room with four 

walls and a ceiling, instead of a partitioned studio, or 
warehouse. 

  Make sure the unit is secure with no gaps where air can escape. 

  Minimize the amount of humidity in the room. For example, run 

the unit as a dehumidifier. 

  To prolong the compressor's life, please wait at least 3 minutes 

before turning the unit back on after shutting it off. 

  Inspect and keep the air filters clean by cleaning regularly. 

  Perform routine maintenance. 

Содержание Koldfront WAC12000W

Страница 1: ...Window Air Conditioner and Heater Owner s Manual For more information on other great EdgeStar products on the web go to http www edgestar com WAC12000W...

Страница 2: ...e outlet with another appliance Do not use this unit with an extension cord and or adapter plug Do not use this unit near flammable gases combustibles or close proximity to heating appliances During o...

Страница 3: ...e LCDI plug This should trip the plug and cut the power to the air conditioner If the plug does not trip and you are able to turn on the unit please contact EdgeStar support DO NOT USE YOUR WINDOW AIR...

Страница 4: ...O WINDOW 6 ATTACH SIDE CURTAINS TO WINDOW FRAME 7 COMPLETING INSTALLATION 8 CONTROL PANEL OPERATIONS 9 TO TURN UNIT ON 9 TO CHANGE TEMPERATURE 9 TO ADJUST FAN SPEEDS 9 TO SELECT OPERATING MODE 9 To op...

Страница 5: ...on the ratings label on the back of your unit and are needed to obtain warranty service You may also want to staple your receipt to this manual as it is the proof of your purchase and is also needed...

Страница 6: ...Parts Identification Side View Front View CAUTION Make sure the drain plug is firmly installed before using the unit to prevent leaking Control Panel Louver Air Outlet Side and Back Vent Front Air Int...

Страница 7: ...at is near an electrical outlet that will be able to provide sufficient power to your unit See the power requirements listed on the product label printed on the side or on the back of your window air...

Страница 8: ...the cabinet Place the air conditioner on cardboard Figure 3 Attaching the Top Channel and Side curtains Make sure to attach the top channel and side curtains prior to installing the cabinet into the w...

Страница 9: ...ow Top View 6 Then insert the bottom of the side curtain housing to the bottom channel on the air conditioner as shown below Bottom View Attaching Foam Adhesive 1 Attach the foam adhesive seal along t...

Страница 10: ...ee starter holes 3 8 deep through the three holes in the cabinet and into the window sill Drill one starter hole 3 8 deep through the hole in the middle of the top rail and into the window frame For V...

Страница 11: ...ur starter holes through the holes in the side curtains into window Screw in four 10 x screws through the holes in the side curtains into the window sill Figure 1 Figure 2 Vinyl Windows Use a 1 8 dril...

Страница 12: ...to the window sash 4 Attach the window lock bracket A to the window sash with two 10 x flat screws D to secure the window in place A B C D 5 Insert Air Conditioner into cabinet 6 Insert front tabs of...

Страница 13: ...ress Fan Speed in four steps Auto Low Medium or High Each time the button is pressed the fan speed mode is shifted NOTE During Dry mode the fan speed is controlled at Low automatically To Select Opera...

Страница 14: ...the compressor shuts off The fan then cycles on for 2 minutes at 10 minute intervals until the room temperature is above the set temperature at which the compressor turns back on and cooling starts T...

Страница 15: ...r for more efficient operation The LED light will illuminate after 250 hours of operation To reset after cleaning the filter press the Check Filter button and the light will go off Digital Display Dis...

Страница 16: ...side to side Additional Tips The Cool mode has an automatic 3 minute timed delay start if the unit is turned off and on quickly This prevents overheating of the compressor and possible circuit breake...

Страница 17: ...epending on function ONE TOUCH button When pushed the system will automatically shift to COOL operation with auto fan speed the setting temperature is 26 C 80 F And the timer setting program will be c...

Страница 18: ...acing 6 You also have the option of cleaning filter with vacuum Warning Never use hot water over 40C 104F to clean the air filter Never attempt to operate the unit without the air filter Cabinet Clean...

Страница 19: ...ner Do not cover the air outlet exhaust while in use Use the timer to operate the unit before it is needed For example set the timer to turn on the unit in cooling mode for 3 or more hours to cool the...

Страница 20: ...ated behind air filter Straighten tube away from coil Compressor shut off by changing modes Wait approximately 3 minutes and listen for compressor to restart when set in the COOL mode Air conditioner...

Страница 21: ...ent sound this is normal Set FAN speed to a higher setting to bring air past cooling coils more frequently If too loud set to a slower FAN setting Window vibration poor installation Refer to installat...

Страница 22: ...of product Window Air Conditioner and Heater Model WAC12000W Voltage Frequency 220V 60Hz Input Power cooling heating 1220W 3500W Current cooling heating 5 5A 15 0A Color White Coolant R410A 17 64 Time...

Страница 23: ...struct in proper usage of the product Damages or operating problems resulting from misuse abuse operation outside environmental specifications uses contrary to instructions provided in the owner s man...

Страница 24: ...m E mail service edgestar com Register your product download owner s manuals access additional troubleshooting resources and obtain more information on other great EdgeStar Koldfront products on the w...

Отзывы: