background image

11 

To Change Temperature: 

Press or hold either the Left (Decrease) or Right (Increase) button until desired temperature is 
seen on the digital display. This temperature will be automatically maintained anywhere between 
62°F (17°C) and 86°F (30°C). 

To Adjust Fan Speeds: 

To select the speed of the fan, press the Fan Speed button which cycles through four (4) steps: 
Auto, Low, Medium, and High. Each time the button is pressed the fan speed mode is shifted to 
the next speed option. 
 
 
 
 

To Select Operating Mode:

 

To choose the operating mode, press the Mode button. Each time you press the button, a mode 
is selected in a sequence that cycles from Auto -> Cool -> Dry -> Fan. The indicator light beside 
the mode button will be illuminated and remain on once the mode is selected.  The unit will 
automatically initiate the Energy Saver function in Auto, Cool and Dry modes. 

To Operate in Auto Mode: 

 

When you set the unit to “Auto” mode the unit will automatically select cooling or fan 
depending on the temperature selected and the current room temperature. The air 
conditioner will automatically maintain room temperature around the selected 
temperature.   

 

In this mode the fan speed cannot be adjusted.  It starts automatically at the appropriate 
speed to reach and maintain the selected temperature most efficiently. 

 
 
 
 
 
 
 
 
 

To Operate in Cool Mode:  

 

When the unit is set to “Cool” mode it will cool the room to maintain the desired set 
temperature.   

  When the desired temperature has been reached, the unit will automatically maintain the 

temperature.  

  Press the Right and Left buttons to adjust the desired temperature and press the Fan 

button to adjust the fan speed. 

To Operate in Dry Mode: 

 

In this mode, the air conditioner will operate as a dehumidifier. Because the conditioned 
space is closed or sealed, some degree of cooling will continue to occur. 

 

In Dry mode the fan runs at Low speed, which cannot be adjusted. 

 

Note:  

 The unit does not constantly take temperature readings. The unit will take a temperature 

reading periodically while operating in AUTO mode, or immediately upon adjustment of the 
desired set temperature.   

 When operating in AUTO MODE the unit may not switch between Cooling and Fan Mode at the 

exact moment when a temperature change has occurred.   

 Room temperature may be different than the temperature sensed in front of the air conditioner. 

 

NOTE: 

While in “Dry” mode, the fan speed is automatically set to Low and cannot be adjusted. 

 
 
 

Содержание Koldfront CAC10000W

Страница 1: ...dow Air Conditioner Owner s Manual For more information on other great EdgeStar and Koldront products on the web go to https www edgestar com To use the EdgeStar self diagnostic tool go to https suppo...

Страница 2: ...his unit near flammable gases combustibles or in close proximity to heating appliances During operation do not remove any part of the outside casing Electrical Requirements A 115 volt 103 5 minimum 12...

Страница 3: ...hould trip the plug and cut the power to the air conditioner If the plug does not trip and you are able to turn on the unit please contact EdgeStar support DO NOT USE YOUR WINDOW AIR CONDITIONER IF TH...

Страница 4: ...PERATIONS 10 Using the Control Panel 10 Digital Display 10 To Turn the Unit On 10 To Change Temperature 11 To Adjust Fan Speeds 11 To Select Operating Mode 11 To Operate in Auto Mode 11 To Operate in...

Страница 5: ...ngs label on the back of your unit and are needed to obtain warranty service You may also want to staple your receipt to this manual as it is the proof of your purchase and is also needed for service...

Страница 6: ...2 Parts Identification Side View Front View CAUTION Make sure the drain plug is firmly installed before using the unit to prevent leaking...

Страница 7: ...choose one that is near an electrical outlet that will be able to provide sufficient power to your unit See the power requirements listed on the product label printed on the side or the back of your...

Страница 8: ...rt brace and test again 2 Measure 8 11 16 from the window jamb and lightly draw a line in pencil NOTE When choosing your window make sure power supply cord is within 6 feet of a grounded 3 prong outle...

Страница 9: ...sealing strip on the inner track 5 Securely attach a siding protection board to the side of the house 6 Place the window platform with the platform tab against the inside of the window track Fasten t...

Страница 10: ...ng three 8x3 8 screws item 17 in the parts supplies list per channel When fastening the screws start with the top screw and make sure that the curved ends on the long end of the channel face back towa...

Страница 11: ...length so that the seal is even with the bottom of the side channel Remove the Front Panel 1 Remove the two 2 front retaining screws from the front frame 2 Gently pull the front out and lift up to rel...

Страница 12: ...he window does not fit snugly against the window panel frame it can be secured with screws Using the partially plugged holes in the window panel frame drill 1 8 pilot holes for the screws Secure the w...

Страница 13: ...front in the proper location Installing Air Conditioner Into a Casement Window Follow the steps listed below to install the air conditioner into the window 1 Using two 2 or more persons safely lift t...

Страница 14: ...ot holes in the side window jambs Secure the side channels using two 8 32x3 4 self threading screws 4 Replace the front panel by reversing the steps in the Remove the Front Panel section Control Panel...

Страница 15: ...elected temperature In this mode the fan speed cannot be adjusted It starts automatically at the appropriate speed to reach and maintain the selected temperature most efficiently To Operate in Cool Mo...

Страница 16: ...nd then one 1 hour increments up to 24 hours The selected time will register in five 5 seconds and the system will automatically revert back to display the previous temperature setting or room tempera...

Страница 17: ...air directional louvers side to side use the center handles as you move side to side Exhaust Control The Exhaust Control allows the air conditioner to either circulate inside air Closed or exhaust air...

Страница 18: ...This button is used to enable the timer Press it twice to cancel the programmed Auto Start Start time See Timer Feature for operating details SPEED This button allows you to cycle through the followin...

Страница 19: ...l the grove aligns with the lock symbol Note In order for the remote to function properly the distance between the remote and the air conditioner should not exceed 16ft 5m Electronics may interfere wi...

Страница 20: ...ing the filter with a vacuum Cabinet Cleaning Be sure to unplug the air conditioner to prevent shock or fire hazard The cabinet and front may be dusted with an oil free cloth or washed with a cloth da...

Страница 21: ...ide Read and follow the guide below to get the best performance and efficiency from your window air conditioner Do not cover the air outlet exhaust while in use Use the timer to operate the unit befor...

Страница 22: ...el cold enough Room temperature is below 62 17 Cooling will not occur until room temperature rises above 62 17 Temperature sensor behind the front grill and air filter is touching the cold evaporator...

Страница 23: ...ner turns on and off frequently Dirty air filter air restricted Clean air filter Outside temperature is extremely hot Set FAN speed to a Higher setting to push more air through the coils Noise when un...

Страница 24: ...duct Casement Window Air Conditioner Model CAC10000W Voltage Frequency 115V 60Hz Cooling Capacity BTUs 10000 Current 8 5A Color White Refrigerant R410A 17 64 oz Timer 24 Hour Dimensions W x D x H 14 1...

Страница 25: ...on or commercial use Labor service transportation and shipping charges for the removal and replacement of defective parts beyond the initial 24 month period Products that have been modified to perform...