background image

14 

Remote Control Operations 

The included remote is a universal remote control. Some functions may be found on the remote 
that this model of air conditioner does not have. If an unavailable function is selected the unit will 
continue operating under its current running status. Use the remote control to change modes, fan 
speed, timer, and temperature settings as well as to set sleep mode. 
 
 
 

 

Using the Remote Control 

 

Button 

Function 

 

This button powers the unit on or off. 

MODE 

This button allows you to cycle through the 
following modes: Auto, Cool, Dry, and Fan. 

 

This button decreases the set temperature, or 
the time when the Timer is enabled. 

 

This button increases the set temperature, or 
the time when the Timer is enabled. 

TIMER 

This button is used to enable the timer. Press it 
twice to cancel the programmed Auto 
Start/Start time.  

See “Timer Feature” for 

operating details. 

SPEED 

This button allows you to cycle through the 
following fan speeds: Auto, Low, Medium or 
High. 

ENERGY 
SAVER 

This button activates the Energy Saver feature.  
Press it again to shut off the feature.  See 
“Energy Saver Feature” section for operating 
details. 

ONE TOUCH 

When this button is pressed the system will 
shift to Cool mode and Auto fan speed.  The 
set temperature will automatically adjust to 
80°F (26°C.)  Pressing will cancel timer 
settings.   

SLEEP 

This button is used to enable the Sleep 
feature.  This feature is available in Auto and 
Cool modes. Press the button again to turn off 
the Sleep feature.  S

ee “Sleep Feature” 

section of this manual for operating details. 

 

Note: Be careful not to drop the remote control. Do not place the remote control in a location 
exposed to direct sunlight. 

Содержание Koldfront CAC10000W

Страница 1: ...dow Air Conditioner Owner s Manual For more information on other great EdgeStar and Koldront products on the web go to https www edgestar com To use the EdgeStar self diagnostic tool go to https suppo...

Страница 2: ...his unit near flammable gases combustibles or in close proximity to heating appliances During operation do not remove any part of the outside casing Electrical Requirements A 115 volt 103 5 minimum 12...

Страница 3: ...hould trip the plug and cut the power to the air conditioner If the plug does not trip and you are able to turn on the unit please contact EdgeStar support DO NOT USE YOUR WINDOW AIR CONDITIONER IF TH...

Страница 4: ...PERATIONS 10 Using the Control Panel 10 Digital Display 10 To Turn the Unit On 10 To Change Temperature 11 To Adjust Fan Speeds 11 To Select Operating Mode 11 To Operate in Auto Mode 11 To Operate in...

Страница 5: ...ngs label on the back of your unit and are needed to obtain warranty service You may also want to staple your receipt to this manual as it is the proof of your purchase and is also needed for service...

Страница 6: ...2 Parts Identification Side View Front View CAUTION Make sure the drain plug is firmly installed before using the unit to prevent leaking...

Страница 7: ...choose one that is near an electrical outlet that will be able to provide sufficient power to your unit See the power requirements listed on the product label printed on the side or the back of your...

Страница 8: ...rt brace and test again 2 Measure 8 11 16 from the window jamb and lightly draw a line in pencil NOTE When choosing your window make sure power supply cord is within 6 feet of a grounded 3 prong outle...

Страница 9: ...sealing strip on the inner track 5 Securely attach a siding protection board to the side of the house 6 Place the window platform with the platform tab against the inside of the window track Fasten t...

Страница 10: ...ng three 8x3 8 screws item 17 in the parts supplies list per channel When fastening the screws start with the top screw and make sure that the curved ends on the long end of the channel face back towa...

Страница 11: ...length so that the seal is even with the bottom of the side channel Remove the Front Panel 1 Remove the two 2 front retaining screws from the front frame 2 Gently pull the front out and lift up to rel...

Страница 12: ...he window does not fit snugly against the window panel frame it can be secured with screws Using the partially plugged holes in the window panel frame drill 1 8 pilot holes for the screws Secure the w...

Страница 13: ...front in the proper location Installing Air Conditioner Into a Casement Window Follow the steps listed below to install the air conditioner into the window 1 Using two 2 or more persons safely lift t...

Страница 14: ...ot holes in the side window jambs Secure the side channels using two 8 32x3 4 self threading screws 4 Replace the front panel by reversing the steps in the Remove the Front Panel section Control Panel...

Страница 15: ...elected temperature In this mode the fan speed cannot be adjusted It starts automatically at the appropriate speed to reach and maintain the selected temperature most efficiently To Operate in Cool Mo...

Страница 16: ...nd then one 1 hour increments up to 24 hours The selected time will register in five 5 seconds and the system will automatically revert back to display the previous temperature setting or room tempera...

Страница 17: ...air directional louvers side to side use the center handles as you move side to side Exhaust Control The Exhaust Control allows the air conditioner to either circulate inside air Closed or exhaust air...

Страница 18: ...This button is used to enable the timer Press it twice to cancel the programmed Auto Start Start time See Timer Feature for operating details SPEED This button allows you to cycle through the followin...

Страница 19: ...l the grove aligns with the lock symbol Note In order for the remote to function properly the distance between the remote and the air conditioner should not exceed 16ft 5m Electronics may interfere wi...

Страница 20: ...ing the filter with a vacuum Cabinet Cleaning Be sure to unplug the air conditioner to prevent shock or fire hazard The cabinet and front may be dusted with an oil free cloth or washed with a cloth da...

Страница 21: ...ide Read and follow the guide below to get the best performance and efficiency from your window air conditioner Do not cover the air outlet exhaust while in use Use the timer to operate the unit befor...

Страница 22: ...el cold enough Room temperature is below 62 17 Cooling will not occur until room temperature rises above 62 17 Temperature sensor behind the front grill and air filter is touching the cold evaporator...

Страница 23: ...ner turns on and off frequently Dirty air filter air restricted Clean air filter Outside temperature is extremely hot Set FAN speed to a Higher setting to push more air through the coils Noise when un...

Страница 24: ...duct Casement Window Air Conditioner Model CAC10000W Voltage Frequency 115V 60Hz Cooling Capacity BTUs 10000 Current 8 5A Color White Refrigerant R410A 17 64 oz Timer 24 Hour Dimensions W x D x H 14 1...

Страница 25: ...on or commercial use Labor service transportation and shipping charges for the removal and replacement of defective parts beyond the initial 24 month period Products that have been modified to perform...

Отзывы: