General Safety 

  Always unplug an appliance from the power supply before attempting any service. Disconnect the 

power cord by grasping the plug, not the cord. 

  Do not allow children or pets to play on or in the appliance.  

  This machine is not intended for use by persons (including children) with reduced physical, sensory or 

mental capabilities, or lack of experience and knowledge, unless they have been given supervision or 
instruction concerning use of the machine by a person responsible for their safety. 

  Do not install or store this appliance where it will be exposed to the weather. 

  Disconnect from the power socket before cleaning or maintenance.  

  If the plug (power cord) is damaged, it must be replaced by the manufacturer or an authorized service 

representative. 

  This machine shall be repaired only by an authorized service representative. Only genuine 

replacement parts should be used. 

  If connected to a circuit protected by fuses, use time-delay fuses with this appliance. 

  Do not lean items against the glass door. 

  Please do not close the door with excessive force. If it is found difficult to close the door, please check 

for obstruction. 

  When you plan to dispose of this unit in the future, please comply with the local waste disposal 

regulations. Remove any doors so that children and pets will not be trapped in the unit. 

 

Содержание AP8000W

Страница 1: ...ranty service should be performed by an authorized service representative only SERVICE MANUAL EdgeStar Small Room Portable Air Conditioner with 71 Pint Dehumidifier MODEL AP8000W Document Type Service...

Страница 2: ...terpretation or misuse of the information provided nor does it assume any liability in connection with its use The safeguards and warnings indicated in this manual do not cover all possible conditions...

Страница 3: ...iance is properly grounded Do not bypass cut or remove the grounding plug If the power cord is damaged it must be replaced by the manufacturer or a qualified technician Do not use extension cords or p...

Страница 4: ...exposed to the weather Disconnect from the power socket before cleaning or maintenance If the plug power cord is damaged it must be replaced by the manufacturer or an authorized service representative...

Страница 5: ...ower 860 W Current 7 9 A Cooling Capacity SACC 4500 BTU Cooling Capacity ASHRAE 8000 BTU Color White Dehumidifying Capacity 71 pints Day Coolant R 410A Timer 24 Hour Dimensions W x H x D 19 25 x 24 75...

Страница 6: ...5 2 Exploded View and Parts List...

Страница 7: ...INTAKE GRILLE 15 EVAPORATOR 48 INTAKE GRILLE 16 DISCHARGE PIPE 49 COVER 17 SUCTION PIPE 50 FIXTURE 18 CAPILARY TUBE 51 COVER 19 FILTER DRYER 52 BRACKET 20 FAN HOUSING 53 PLUG 21 FAN HOUSING 54 SENSOR...

Страница 8: ...7 3 Wiring Diagram 4 Refrigerant System Diagram...

Страница 9: ...rms to the chart below When TA TS for 1 minute the compressor turns off When TA TS 2 the compressor turns on 5 3 Fan Only Mode Green Light If the temperature can t be controlled by the selected mode a...

Страница 10: ...in Dehumidifying mode you must manually drain the water from the unit Additionally the ambient temperature in the room will probably rise by a few degrees if you do not use the exhaust hose You will b...

Страница 11: ...l room temperature rises above 61 F 16 C Unit is not in cooling mode Set the unit to cooling mode blue light is on Set temperature is too high Set to a Lower temperature Air filter is dirty Clean filt...

Страница 12: ...Attach the drain plug Base plate is cracked Replace base plate Sounds or vibration When unit is turned on or off the outer shell pops or clicks Normal sound Outer shell is contracting or expanding an...

Страница 13: ...l St Suite 1800 Austin TX 78754 support edgestar com service edgestar com edgestar com Warranty service should be performed by an authorized service representative only DATE REVISION NOTES 04 11 2018...