background image

 
 

 
 

CONTENTS 

 

CONTENTS ....................................................................................................................................... 1 
SAFETY PRECAUTIONS ..................................................................................................................... 1 

ELECTRICAL SAFETY ..................................................................................................................... 2 
GENERAL SAFETY ......................................................................................................................... 3 

1 SPECIFICATIONS ........................................................................................................................... 4 
2 EXPLODED VIEW AND PARTS LIST ................................................................................................ 5 
3 WIRING DIAGRAM ........................................................................................................................ 7 
4 REFRIGERANT SYSTEM DIAGRAM ................................................................................................ 7 
5 MODES AND OPERATING CONDITIONS ....................................................................................... 8 

5.1 TERMS AND DEFINITIONS ..................................................................................................... 8 
5.2 COOLING MODE (BLUE LIGHT) .............................................................................................. 8 
5.3 FAN ONLY MODE (GREEN LIGHT) .......................................................................................... 8 
5.4 DEHUMIDIFY MODE (AMBER LIGHT) .................................................................................... 9 
5.5 OVERFLOW PREVENTION ...................................................................................................... 9 
5.6 COMPRESSOR PROTECTION .................................................................................................. 9 

6 TROUBLESHOOTING ................................................................................................................... 10 

 

 

SAFETY PRECAUTIONS 

 

WARNING: This manual and the information contained herein is intended for use 
by certified technicians.  The manufacturer or seller is not responsible for the 
interpretation or misuse of the information provided, nor does it assume any 
liability in connection with its use.  

 

 

The safeguards and warnings indicated in this manual do not cover all possible 
conditions which may occur. Common sense, caution, and care must be 
exercised.

 

 

 

To prevent electric shock, always unplug an appliance from the power supply before attempting 
any service.  

 

Disconnect the power cord by grasping the plug, not the cord. 

 

Do not bypass, cut, or remove the grounding plug.   

 

Prevent water from spilling onto electric elements or the machine parts. 

 

Always refer to the rating label on the appliance for rated current and voltage. 

 

Always check line voltage and amperage. 

 

Always use exact replacement parts. 

 

Any attempt to repair a major appliance may result in personal injury and property damage. 

Содержание AP8000W

Страница 1: ...ranty service should be performed by an authorized service representative only SERVICE MANUAL EdgeStar Small Room Portable Air Conditioner with 71 Pint Dehumidifier MODEL AP8000W Document Type Service...

Страница 2: ...terpretation or misuse of the information provided nor does it assume any liability in connection with its use The safeguards and warnings indicated in this manual do not cover all possible conditions...

Страница 3: ...iance is properly grounded Do not bypass cut or remove the grounding plug If the power cord is damaged it must be replaced by the manufacturer or a qualified technician Do not use extension cords or p...

Страница 4: ...exposed to the weather Disconnect from the power socket before cleaning or maintenance If the plug power cord is damaged it must be replaced by the manufacturer or an authorized service representative...

Страница 5: ...ower 860 W Current 7 9 A Cooling Capacity SACC 4500 BTU Cooling Capacity ASHRAE 8000 BTU Color White Dehumidifying Capacity 71 pints Day Coolant R 410A Timer 24 Hour Dimensions W x H x D 19 25 x 24 75...

Страница 6: ...5 2 Exploded View and Parts List...

Страница 7: ...INTAKE GRILLE 15 EVAPORATOR 48 INTAKE GRILLE 16 DISCHARGE PIPE 49 COVER 17 SUCTION PIPE 50 FIXTURE 18 CAPILARY TUBE 51 COVER 19 FILTER DRYER 52 BRACKET 20 FAN HOUSING 53 PLUG 21 FAN HOUSING 54 SENSOR...

Страница 8: ...7 3 Wiring Diagram 4 Refrigerant System Diagram...

Страница 9: ...rms to the chart below When TA TS for 1 minute the compressor turns off When TA TS 2 the compressor turns on 5 3 Fan Only Mode Green Light If the temperature can t be controlled by the selected mode a...

Страница 10: ...in Dehumidifying mode you must manually drain the water from the unit Additionally the ambient temperature in the room will probably rise by a few degrees if you do not use the exhaust hose You will b...

Страница 11: ...l room temperature rises above 61 F 16 C Unit is not in cooling mode Set the unit to cooling mode blue light is on Set temperature is too high Set to a Lower temperature Air filter is dirty Clean filt...

Страница 12: ...Attach the drain plug Base plate is cracked Replace base plate Sounds or vibration When unit is turned on or off the outer shell pops or clicks Normal sound Outer shell is contracting or expanding an...

Страница 13: ...l St Suite 1800 Austin TX 78754 support edgestar com service edgestar com edgestar com Warranty service should be performed by an authorized service representative only DATE REVISION NOTES 04 11 2018...

Отзывы: