4. Remove the fitting from the
Thermocouple and install by
tightening the tapered thread end
into the manifold.
5. Tighten the fitting so that it is
securely seated.
6. Install the probe into the fitting,
and tighten the top nut of the fit
-
ting just tight enough to keep the
probe firmly mounted.
NOTE: Ideally the tip of the fitting
would be less than or flush with the
inside of the exhaust flow path.
7. Make sure that the probe
cable is positioned to allow best
path and minimal bending for
routing to the fire wall.
NOTE: The probe will move ap-
proximately 90 Deg. clockwise in the
direction the nut is tightened. Before
fully tightening the nut, make sure
the cable starts 90 Degrees from
the final resting position. When
tightened, the cable will be correctly
positioned.
Starting
Position
Tightened
Position
90 Deg.
To Fire wall
Fitting
Flush
Nut
Probe
Exhaust Manifold Wall
Fitting
Tapped Hole