Connect Network Cables

1.

For the RJ-45 ports, connect Category 5e or better twisted-pair 
cable.

2.

First install SFP/SFP+ transceivers and then connect fiber optic 
cabling to the transceiver ports. 

The following transceivers are supported in the SFP+ ports:

10GBASE-SR

1000BASE-SX

3.

As connections are made, check the port status LEDs to be sure 
the links are valid. 

Make Initial Configuration Changes

1.

Connect a PC to one of the SD-WAN Edge CPE’s LAN ports. 

2.

Log in to the web interface using the default management IP 
address 192.168.100.1 (there is no user name or password).

3.

Configure the Barrista controller IP address and port through 
one of the following methods.

DHCP: Automatic configuration.

Static: Manually set the IP address, subnet mask, default 
gateway, and DNS servers.

PPPoE: Set the PPPoE username and password.

Click “Save” to confirm the configuration and enable the SD-WAN 

Edge CPE to communicate with the Barrista controller.

Hardware Specifications

5

1

2

6

Form Factor

1 RU rackmount

Dimensions 

(W x D x H): 

442 x 298.3 x 43.6 mm (17.4 x 11.74 x 1.72 in.)

Weight

4.43 kg (9.77 lb), with two installed PSUs

CPUs

CPU Intel® Atom™ Processor C3758 SoC (14nm)

2.2 GHz

Support 8 cores

Memory

Sockets: 2x260pin DDR4 SODIMM slots

Type: 2 x 8GB DDR4-2400 ECC DRAM (32GB max)

Local Storage 1 x M.2 SATA 3 SSD, 128GB

I/O Interfaces 1 x USB 3.0 Type A 

1 x RJ-45 serial console

Network 

Interfaces

4 SFP+ 10GbE ports

8 RJ-45 GbE ports

Expansion

Type: Internal Mini PCIe slots x2

Accelerator

Advanced Technologies: Intel QuickAssist, VT-x, VT-

d, EPT, AES-NI

Storage Encryption: TPM V2.0 

Power Supply 

Unit Rating

Input: AC 100V to 240V @ 50-60 Hz

Type: 300 W

System 

Cooling

Two active fans in rear, support smart fan speed 

control

Temperature

Operating: 0 °C to 45 °C (32 °F to 113 °F)

Storage: -40 °C to 70 °C (-40 °F to 158 °F)

Humidity

Operating: 5% to 95% (non-condensing)

Storage: 5% to 90% (non-condensing)

Compliances CE

FCC 

CB

UL/cUL

RoHS 2.0

Содержание SDW101

Страница 1: ...vice 2 Connect an external AC power source to the PSU Verify Device is Powered On 1 Verify the device is powered on by checking the Power LED When operating normally the Power LED should be on green Warning This equipment is not suitable for use in locations where children are likely to be present Avertissement Cet équipement ne peut pas être utilisé dans des endroits où des enfants sont susceptib...

Страница 2: ...firm the configuration and enable the SD WAN Edge CPE to communicate with the Barrista controller Hardware Specifications 5 1 2 6 Form Factor 1 RU rackmount Dimensions W x D x H 442 x 298 3 x 43 6 mm 17 4 x 11 74 x 1 72 in Weight 4 43 kg 9 77 lb with two installed PSUs CPUs CPU Intel Atom Processor C3758 SoC 14nm 2 2 GHz Support 8 cores Memory Sockets 2x260pin DDR4 SODIMM slots Type 2 x 8GB DDR4 2...

Страница 3: ... 2013 ED 4 0 Power frequency magnetic field immunity test according to IEC 61000 4 8 2009 ED 2 0 Voltage dips short interruptions and voltage variations immunity test according to IEC 61000 4 11 2020 ED 3 0 LVD EN 62368 1 2014 A11 2017 The Declaration of Conformity DoC can be obtained from www edge core com support download Japan VCCI Class A Laser Safety Warning Fiber Optic Port Safety Avertissme...

Страница 4: ... T par le biais d un transformateur d isolement à rapport 1 1 avec un point secondaire de connexion portant l appellation Neutre et avec raccordement direct à la terre masse Bitte unbedingt vor dem Einbauen des Switches die folgenden Sicherheitsanweisungen durchlesen Warnung Die Installation und der Ausbau des Geräts darf nur durch Fachpersonal erfolgen Das Gerät sollte nicht an eine ungeerdete We...

Страница 5: ...smission lorsque ce dernier est sous tension Avertissement Lorsque vous utilisez un dispositif fibre de type SFP SFP en ce qui concerne la sécurité assurez vous qu il puisse fonctionner à une température inférieure à la température maximale de fonctionnement recommandée du produit Utilisez également un émetteur récepteur laser SFP SFP de classe 1 agrée Attention La manipulation de cet équipement r...

Отзывы: