IPv6 Interface Commands
60-8
60
universal/local bit in the address and inserting the hexadecimal number FFFE
between the upper and lower three bytes of the of the MAC address.
For example, if a device had an EUI-48 address of 28-9F-18-1C-82-35, the
global/local bit must first be inverted to meet EUI-64 requirements (i.e., 1 for
globally defined addresses and 0 for locally defined addresses), changing 28
to 2A. Then the two bytes FFFE are inserted between the OUI (i.e., company
id) and the rest of the address, resulting in a modified EUI-64 interface
identifier of 2A-9F-18-FF-FE-1C-82-35.
• This host addressing method allows the same interface identifier to be used
on multiple IP interfaces of a single device, as long as those interfaces are
attached to different subnets.
Example
This example uses the general network prefix of 2001:0DB8:0:1::/64 used in an
earlier example, and specifies that the EUI-64 interface identifier be used in the
lower 64 bits of the address.
Related Commands
ipv6 address autoconfig (60-6)
show ipv6 interface (60-10)
Console(config)#interface vlan 1
Console(config-if)#ipv6 address 2001:0DB8:0:1::/64 eui-64
Console(config-if)#end
Console#show ipv6 interface
Vlan 1 is up
IPv6 is enable.
Link-local address:
FE80::200:E8FF:FE90:0/64
Global unicast address(es):
2001:DB8::1:200:E8FF:FE90:0, subnet is 2001:DB8:0:1::/64
Joined group address(es):
FF01::1/16
FF02::1/16
FF02::1:FF90:0/104
MTU is 1500 bytes.
ND DAD is enabled, number of DAD attempts: 1.
ND retransmit interval is 1000 milliseconds
Содержание Direk Tronik 24/48-Port
Страница 2: ......
Страница 4: ...ES4524D ES4548D F0 0 0 4 E112006 CS R01 149100030400A...
Страница 22: ...xxii Tables...
Страница 26: ...xxvi Figures...
Страница 28: ...Getting Started...
Страница 50: ...Initial Configuration 2 14 2...
Страница 52: ...Switch Management Configuring Domain Name Service 29 1 Switch Clustering 30 1...
Страница 68: ...Basic System Settings 4 8 4...
Страница 118: ...Simple Network Management Protocol 11 18 11...
Страница 142: ...Configuring 802 1X Port Authentication 14 8 14...
Страница 154: ...Access Control Lists 15 12 15...
Страница 232: ...Configuring Protocol Based VLANs 25 4 25...
Страница 252: ...Quality of Service 27 8 27...
Страница 282: ...Using the Command Line Interface 31 10 31...
Страница 290: ...General Commands 33 6 33...
Страница 300: ...System Management Commands 34 10 34...
Страница 308: ...File Management Commands 35 8 35...
Страница 326: ...Event Logging Commands 37 8 37...
Страница 336: ...Time Commands 39 6 39...
Страница 406: ...Access Control List Commands 44 18 44...
Страница 418: ...Interface Commands 45 12 45...
Страница 432: ...Broadcast Storm Control Commands 47 2 47...
Страница 436: ...Rate Limit Commands 49 2 49...
Страница 478: ...VLAN Commands 52 18 52...
Страница 508: ...Quality of Service Commands 56 10 56...
Страница 518: ...Multicast Filtering Commands 57 10 57...
Страница 532: ...IPv4 Interface Commands 59 6 59...
Страница 560: ...IPv6 Interface Commands 60 28 60...
Страница 566: ...Switch Cluster Commands 61 6 61...
Страница 568: ...Appendices...
Страница 572: ...Software Specifications A 4 A TACACS Authentication Client MIB TCP MIB RFC 2012 Trap RFC 1215 UDP MIB RFC 2013...
Страница 582: ...Glossary Glossary 8...
Страница 587: ......
Страница 588: ...ES4524D ES4548D E112006 CS R01 149100030400A...