![Edge-Core Direk Tronik 24/48-Port Скачать руководство пользователя страница 222](http://html1.mh-extra.com/html/edge-core/direk-tronik-24-48-port/direk-tronik-24-48-port_management-manual_2359667222.webp)
VLAN Configuration
23-14
23
3. After packet classification through the switching process, the packet is written to
memory with one tag (an outer tag) or with two tags (both an outer tag and inner
tag).
4. The switch sends the packet to the proper egress port.
5. If the egress port is an untagged member of the SPVLAN, the outer tag will be
stripped. If it is a tagged member, the outgoing packets will have two tags.
Layer 2 Flow for Packets Coming into a Tunnel Uplink Port
An uplink port receives one of the following packets:
• Untagged
• One tag (CVLAN or SPVLAN)
• Double tag (CVLAN + SPVLAN)
The ingress process does source and destination lookups. If both lookups are
successful, the ingress process writes the packet to memory. Then the egress
process transmits the packet. Packets entering a QinQ uplink port are processed in
the following manner:
1. If incoming packets are untagged, the PVID VLAN native tag is added.
2. If the ether-type of an incoming packet (single or double tagged) is not equal to
the TPID of the uplink port, the VLAN tag is determined to be a Customer VLAN
(CVLAN) tag. The uplink port’s PVID VLAN native tag is added to the packet.
This outer tag is used for learning and switching packets within the service
provider’s network. The TPID must be configured on a per port basis, and the
verification cannot be disabled.
3. If the ether-type of an incoming packet (single or double tagged) is equal to the
TPID of the uplink port, no new VLAN tag is added. If the uplink port is not the
member of the outer VLAN of the incoming packets, the packet will be dropped
when ingress filtering is enabled. If ingress filtering is not enabled, the packet will
still be forwarded. If the VLAN is not listed in the VLAN table, the packet will be
dropped.
4. After successful source and destination lookup, the packet is double tagged. The
switch uses the TPID of 0x8100 to indicate that an incoming packet is
double-tagged. If the outer tag of an incoming double-tagged packet is equal to
the port TPID and the inner tag is 0x8100, it is treated as a double-tagged
packet. If a single-tagged packet has 0x8100 as its TPID, and port TPID is not
0x8100, a new VLAN tag is added and it is also treated as double-tagged packet.
5. If the destination address lookup fails, the packet is sent to all member ports of
the outer tag's VLAN.
6. After packet classification, the packet is written to memory for processing as a
single-tagged or double-tagged packet.
7. The switch sends the packet to the proper egress port.
8. If the egress port is an untagged member of the SPVLAN, the outer tag will be
stripped. If it is a tagged member, the outgoing packet will have two tags.
Содержание Direk Tronik 24/48-Port
Страница 2: ......
Страница 4: ...ES4524D ES4548D F0 0 0 4 E112006 CS R01 149100030400A...
Страница 22: ...xxii Tables...
Страница 26: ...xxvi Figures...
Страница 28: ...Getting Started...
Страница 50: ...Initial Configuration 2 14 2...
Страница 52: ...Switch Management Configuring Domain Name Service 29 1 Switch Clustering 30 1...
Страница 68: ...Basic System Settings 4 8 4...
Страница 118: ...Simple Network Management Protocol 11 18 11...
Страница 142: ...Configuring 802 1X Port Authentication 14 8 14...
Страница 154: ...Access Control Lists 15 12 15...
Страница 232: ...Configuring Protocol Based VLANs 25 4 25...
Страница 252: ...Quality of Service 27 8 27...
Страница 282: ...Using the Command Line Interface 31 10 31...
Страница 290: ...General Commands 33 6 33...
Страница 300: ...System Management Commands 34 10 34...
Страница 308: ...File Management Commands 35 8 35...
Страница 326: ...Event Logging Commands 37 8 37...
Страница 336: ...Time Commands 39 6 39...
Страница 406: ...Access Control List Commands 44 18 44...
Страница 418: ...Interface Commands 45 12 45...
Страница 432: ...Broadcast Storm Control Commands 47 2 47...
Страница 436: ...Rate Limit Commands 49 2 49...
Страница 478: ...VLAN Commands 52 18 52...
Страница 508: ...Quality of Service Commands 56 10 56...
Страница 518: ...Multicast Filtering Commands 57 10 57...
Страница 532: ...IPv4 Interface Commands 59 6 59...
Страница 560: ...IPv6 Interface Commands 60 28 60...
Страница 566: ...Switch Cluster Commands 61 6 61...
Страница 568: ...Appendices...
Страница 572: ...Software Specifications A 4 A TACACS Authentication Client MIB TCP MIB RFC 2012 Trap RFC 1215 UDP MIB RFC 2013...
Страница 582: ...Glossary Glossary 8...
Страница 587: ......
Страница 588: ...ES4524D ES4548D E112006 CS R01 149100030400A...