Initial Configuration
2-10
2
2.
From the interface prompt, type “ipv6 address autoconfig” and press <Enter>.
Enabling SNMP Management Access
The switch can be configured to accept management commands from Simple
Network Management Protocol (SNMP) applications such as HP OpenView. You
can configure the switch to (1) respond to SNMP requests or (2) generate SNMP
traps.
When SNMP management stations send requests to the switch (either to return
information or to set a parameter), the switch provides the requested data or sets the
specified parameter. The switch can also be configured to send information to
SNMP managers (without being requested by the managers) through trap
messages, which inform the manager that certain events have occurred.
The switch includes an SNMP agent that supports SNMP version 1, 2c, and 3
clients. To provide management access for version 1 or 2c clients, you must specify
a community string. The switch provides a default MIB View (i.e., an SNMPv3
construct) for the default “public” community string that provides read access to the
entire MIB tree, and a default view for the “private” community string that provides
read/write access to the entire MIB tree. However, you may assign new views to
version 1 or 2c community strings that suit your specific security requirements (see
“Setting SNMPv3 Views” on page 11-16).
Community Strings (for SNMP version 1 and 2c clients)
Community strings are used to control management access to SNMP version 1 and
2c stations, as well as to authorize SNMP stations to receive trap messages from
the switch. You therefore need to assign community strings to specified users, and
set the access level.
Console(config)#interface vlan 1
45-1
Console(config-if)#ipv6 address autoconfig
60-6
Console(config-if)#end
Console#show ipv6 interface
60-10
Vlan 1 is up
IPv6 is enable.
Link-local address:
FE80::212:CFFF:FE0B:4600/64
Global unicast address(es):
2005::212:CFFF:FE0B:4600, subnet is 2005:0:0:0::/64
3FFE:501:FFFF:100:212:CFFF:FE0B:4600, subnet is
3FFE:501:FFFF:100::/64
Joined group address(es):
FF01::1/16
FF02::1/16
FF02::1:FF0B:4600/104
MTU is 1500 bytes.
ND DAD is enabled, number of DAD attempts: 1.
ND retransmit interval is 1000 milliseconds
Console#
Содержание Direk Tronik 24/48-Port
Страница 2: ......
Страница 4: ...ES4524D ES4548D F0 0 0 4 E112006 CS R01 149100030400A...
Страница 22: ...xxii Tables...
Страница 26: ...xxvi Figures...
Страница 28: ...Getting Started...
Страница 50: ...Initial Configuration 2 14 2...
Страница 52: ...Switch Management Configuring Domain Name Service 29 1 Switch Clustering 30 1...
Страница 68: ...Basic System Settings 4 8 4...
Страница 118: ...Simple Network Management Protocol 11 18 11...
Страница 142: ...Configuring 802 1X Port Authentication 14 8 14...
Страница 154: ...Access Control Lists 15 12 15...
Страница 232: ...Configuring Protocol Based VLANs 25 4 25...
Страница 252: ...Quality of Service 27 8 27...
Страница 282: ...Using the Command Line Interface 31 10 31...
Страница 290: ...General Commands 33 6 33...
Страница 300: ...System Management Commands 34 10 34...
Страница 308: ...File Management Commands 35 8 35...
Страница 326: ...Event Logging Commands 37 8 37...
Страница 336: ...Time Commands 39 6 39...
Страница 406: ...Access Control List Commands 44 18 44...
Страница 418: ...Interface Commands 45 12 45...
Страница 432: ...Broadcast Storm Control Commands 47 2 47...
Страница 436: ...Rate Limit Commands 49 2 49...
Страница 478: ...VLAN Commands 52 18 52...
Страница 508: ...Quality of Service Commands 56 10 56...
Страница 518: ...Multicast Filtering Commands 57 10 57...
Страница 532: ...IPv4 Interface Commands 59 6 59...
Страница 560: ...IPv6 Interface Commands 60 28 60...
Страница 566: ...Switch Cluster Commands 61 6 61...
Страница 568: ...Appendices...
Страница 572: ...Software Specifications A 4 A TACACS Authentication Client MIB TCP MIB RFC 2012 Trap RFC 1215 UDP MIB RFC 2013...
Страница 582: ...Glossary Glossary 8...
Страница 587: ......
Страница 588: ...ES4524D ES4548D E112006 CS R01 149100030400A...