background image

1)  Unpackage heater. We recommend keeping the packaging for off-season storage and any transporting needs.

2)  Find a level and unobstructed location to place the unpackaged heater.

3)  Plug the power cord directly into an unused grounded 110 volt 15 amp or higher circuit receptacle.

4)  Remove the tab in the remote control to activate the battery of the remote control. 

5)  For the Wall-Hugger ONLY: Make sure the POWER SUPPLY button, on the back of the unit, is in the ON position.

6)  Press the POWER button in the control panel to turn on the heater. 

7)  To turn the heater off, press the POWER button; the fan will continue to run until all of the heat has been expelled.

Display Setting: The GEN2 and Wall-Hugger are equipped with multiple temperature scales, i.e. Fahrenheit and Celsius. To change between these scales, 

press and hold the QUIET/LOW button until the display flashes. Pressing the TIMER button will cycle through the scales. Stop pressing the TIMER button 

once your preference scale is displayed. The display will stop flashing in a few moments. You can continue normal operation of the heater after the display 

stops flashing.
Auto ON Timer: With the heater OFF, press the TIMER button to select the number of hours you want the heater to wait until it powers on. You can select 

between 1-12 hours for the GEN2 and 1-24 with the Wall-Hugger. Heater will power on at the last heat setting it was operated at.
Auto OFF Timer: With the heater ON, press the TIMER button to select the number of hours you want the heater to operate before it turns off. 

You can select between 1-12 hours for the GEN2 and 1-24 with the Wall-Hugger.
To disengage the timer feature, simply press the POWER button or press the TIMER button until the timer is no longer indicated on the display.
Air Purification Function (Upgrade Kit Sold Separately)
Both units can easily be upgraded to include air purification technology. To upgrade, look for the EdenPURE

®

 Air Purification Upgrade Kit (sold sepa-

rately). Follow the instructions included with the kit to install it inside the heater. 
GEN2 NOTE: If the PURIFIER button is pushed WITHOUT the optional upgrade kit, the message “Replace UV Bulb” will be displayed on the 

control panel. This message will remain until the PURIFIER button is pushed again.
Wall-Hugger NOTE: If the Wall-Hugger is equipped with the same air purification kit, the purification function cannot be turned off while the 

heater is running. It will always run in conjunction with the heater.
Quiet/Low Function
: Press the QUIET/LOW button when you wish to run the unit at a lower noise/power level.

EdenPURE

®

 Heaters come equipped with an easy access washable lifetime filter. 

IMPORTANT INFORMATION: If you have allergies and/or are sensitive to dust, you will want to use this filter. When choosing to use the filter, it 

must be cleaned on a regular basis; a clogged filter will cause the heater to not work to its full capacity. 
Using the heater with the dust filter attached is an optional feature. Operating the heater without the filter will in no way harm or alter the operation of 

the heater.  If you are not sensitive to dust or do not want to clean the filter daily, please remove it from the back of unit and use your heater without it.
To Clean the Filter:
1)  Unscrew the knob screw of the filter to release the filter cover and pull it straight out.

2)  Run warm tap water over the filter, the opposite direction of air flow, until water runs clear.  The filter might excrete some filtered residue, 

so be cautious not to drip on any stainable surfaces such as carpeting. You can also soak the filter in water mixed with a small amount of 

mild dish soap (don’t forget to rinse with water after soaking filter).

3)  Shake the filter over a sink until excess water is removed and allow it to drip dry completely before reinstalling.  DO NOT force the filter 

to dry using any alternative methods.

4)  Reinstall the filter to the rear of the unit by positioning the filter back in place.

5)  If using the optional HEPA filter that comes with the Air Purification Upgrade Kit, it can be cleaned by removing all dust and dirt with a 

vacuum attachment. Do not get the HEPA filter wet.

Resetting the “Clean Filter” Notification on the GEN2 - A “Clean Filter” notification will be displayed on the control panel after 720 hours of 

operation. To reset the notification, press and hold the PURIFIER button for 5 seconds.

PRODUCT SETUP

PRODUCT MAINTENANCE

FUNCTIONS

Cabinet Care – Wipe clean with a soft damp cloth.
Heater Storage – When the heater is not going to be used for an extended period of time, please do the following: 

  1)  Unplug the heater.   

  2)  Wind up electrical cord so as to keep it off of the ground.   

  3)  Cover the heater to prevent dust from accumulating on filter or internally.   

  4)  Store the heater in a dry, low dust environment.

GEN2

Wall-HuGGEr

Содержание Wall-Hugger

Страница 1: ...NT SAVE THESE INSTRUCTIONS To ensure you get the best results from your portable heater please read this manual first and keep it for future ref erence For additional information please contact your place of purchase or call 1 800 225 6595 Thank you for choosing EdenPURE ...

Страница 2: ...htub or other water container 7 Do not run the cord under carpeting Do not cover the cord with throw rugs runners or similar coverings Arrange the cord away from traffic areas and where it will not be tripped over 8 To disconnect the heater turn the unit off then remove the plug from the outlet once it has stopped running 9 Do not plug the heater into any other cord connected device such as a powe...

Страница 3: ...er is equipped with the same air purification kit the purification function cannot be turned off while the heater is running It will always run in conjunction with the heater Quiet Low Function Press the QUIET LOW button when you wish to run the unit at a lower noise power level EdenPURE Heaters come equipped with an easy access washable lifetime filter IMPORTANT INFORMATION If you have allergies ...

Страница 4: ... cold floor and heat rises which in turn will display a cooler temperature than elevated or external thermostats The best way to operate your heater is to just set it to a temperature that feels comfortable to you SERVICE For repairs or service please visit your place of purchase call 1 800 225 6595 or visit www edenpureservice com WARNING ANY REQUIRED SERVICE OTHER THAN FILTER MAINTENANCE SHOULD ...

Отзывы: